UNT-SVX041D-EN 7
Vertical High Rise Fan
Coil
Digits 1, 2, 3 - Unit Type
FCV = Vertical High Rise Fan Coil
Digit 4 - Development Sequence
A = Development Sequence
Digits 5,6,7 - Unit Size
030 = 300 CFM
040 = 400 CFM
060 = 600 CFM
080 = 800 CFM
100 = 1000 CFM
120 = 1200 CFM
Digit 8 - Unit Voltage (Volts/Hz/
Phase)
1 = 115/60/1
2 = 208/60/1
3 = 277/60/1
4 = 230/60/1
Digit 9 - Cabinet Options
A = Single Unit
B = Primary Unit
C = Secondary Unit
Digits 10, 11 - Design Sequence
** = Design Sequence
Digit 12 - Discharge
1=Front Only
2=Right Only
3 = Left Only
4 = Top Only
A = Front / Right
B = Front / Left
C = Right / Left
Digit 13 - Outside Air Type
0 = Plug Panel Only
Digit 14 - Discharge Grille
0=None
1 = Single Deflection Grille
Aluminum
2 = Double Deflection Grille
Aluminum
3 = Single Deflection Grille White
4 = Double Deflection Grille White
Digit 15 - Return Air Panel Color
0 = No Front Panel
7 = White
Digit 16 - Return Air Panel
0=None
A = Louvered Panel
B = Return Air Door
Digit 17 - Motor Type
A = ECM Free Discharge
B = ECM High Static
C = ECM Free Discharge Low FLA
D = ECM High Static Low FLA
Digit 18 - Main Coil/Aux Coil
A = 3 Row Cooling only
B = 4 Row Cooling only
C = 3 Row Changeover
D = 4 Row Changeover
E = 3 Row Cooling / 1 Row Reheat
F = 4 Row Cooling / 1 Row Reheat
G = 3 Row Cooling / 2 Row Reheat
Digit 19 - Drain Pan
1 = Stainless Steel
2=PVC
Digits 20, 21, 22 - Electric Heat
kW
000 = No Electric Heat
005 = 0.5 kW (208V 0.4 kW)
010 = 1 kW (208V 0.8 kW)
015 = 1.5 kW (208V 1.1 kW)
020 = 2 kW (208V 1.5 kW)
025 = 2.5 kW (208V 1.9 kW)
030 = 3 kW (208V 2.3 kW)
040 = 4 kW (208V 3 kW)
050 = 5 kW (208V 3.8 kW)
060 = 6 kW (208V 4.5 kW)
070 = 7 kW (208V 5.3 kW)
080 = 8 kW (208V 6 kW)
100 = 10 kW
Digit 23 - Disconnect Switch
0=None
D = Disconnect Switch
Digit 24 - Filter Type
0 = No Filter
1 = 1-in. Throw Away or MERV 2 Filter
2 = 1-in. MERV 8 Filter
3 = 1-in. Throw Away Filter Plus 1
Extra
4 = 1-in. MERV 8 Filter Plus 1 Extra
Digit 25 - Main Control Valve
Type
A = 2-Way 2-Position N.C. Valve
B = 2-Way 2-Position N.O. Valve
C = 3-Way 2-Position N.C. Valve
D = 3-Way 2-Position N.O. Valve
E = 2-Way Modulating
F = 3-Way Modulating
G = 2-Way Analog (2-10 VDC)
H = 3-Way Analog (2-10 VDC)
Digit 26 - Main Control Valve Cv
A = 2-Way 1.4 Cv
B = 2-Way 2.4 Cv
C = 2-Way 3.4 Cv
D = 3-Way 1.0 Cv
E = 3-Way 2.7 Cv
F = 3-Way 4.6 Cv
Digit 27 - Auxiliary Control Valve
Type
0=None
A = 2-Way 2-Position N.C. Valve
B = 2-Way 2-Position N.O. Valve
C = 3-Way 2-Position N.C. Valve
D = 3-Way 2-Position N.O. Valve
E = 2-Way Modulating
F = 3-Way Modulating
G = 2-Way Analog (2-10 VDC)
H = 3-Way Analog (2-10 VDC)
Digit 28 - Auxiliary Control Valve
Cv
0=None
A = 2-Way 1.4 Cv
B = 2-Way 2.4 Cv
C = 2-Way 3.4 Cv
D = 3-Way 1.0 Cv
E = 3-Way 2.7 Cv
F = 3-Way 4.6 Cv
Digit 29 - Piping Package
1 = Basic with Circuit Setter
3 = Deluxe with Circuit Setter
4 = Deluxe with Auto Flow
Digit 30 - Main Autoflow GPM
0=None
A = 0.50 GPM
B = 0.75 GPM
C = 1.0 GPM
D = 1.5 GPM
E = 2.0 GPM
F = 2.5 GPM
G = 3.0 GPM
H = 3.5 GPM
J = 4.0 GPM
K = 4.5 GPM
L = 5.0 GPM
M = 6.0 GPM
N = 7.0 GPM
P = 8.0 GPM
Digit 31 - Auxiliary Autoflow
GPM
0=None
A = 0.50 GPM
B = 0.75 GPM
C = 1.0 GPM
D = 1.5 GPM
E = 2.0 GPM
F = 2.5 GPM
G = 3.0 GPM
H = 3.5 GPM
J = 4.0 GPM
K = 4.5 GPM
L = 5.0 GPM
M = 6.0 GPM
N = 7.0 GPM
P = 8.0 GPM
Digit 32 - Control Type
1 = CSTI
2 = CSTI with Fan Status
3 = UC400-B
4 = UC400-B with Air-Fi
®
WCI
Model Number Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane FCV and is the answer not in the manual?

Trane FCV Specifications

General IconGeneral
BrandTrane
ModelFCV
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals