Model Number Descriptions
16 OAU-SVX007A-EN
Digit 22 — Heater Capacity —
Primary Heat Source
Digit 23 — Heat Capacity —
Secondary Heat Source
Digit 24 — Corrosive Environment
Package
0 = No Corrosive Package
1 = S/S Interior, S/S Coil Casing
2 = S/S Interior, Eco Coated Coils
3 = S/S Interior, Copper/Copper Evap
Coil
4 = S/S Coil Casing
5 = S/S Interior
6 = Eco Coated Coils
7 = S/S Coil Casing with Eco Coated
Coils
8 = Copper/Copper Evap, HGRH Coils
9 = Corrosion Resistant Package
Digits 25, 26 — Unit Controls
00 = Non DDC – Electromechanical
AC = Trane – Discharge Air Control
w/BACnet (No Display)
AD = Trane – Space Control w/BACnet
(No Display)
AF = Trane – Discharge Air Control
w/BACnet w/Display
AG = Trane – Space Control W/BACnet
w/Display
AL = Trane – Multi-Zone Vav Control
w/BACnet w/Display
AN = Trane – Multi-Zone Vav Control
w/BACnet (No Display)
AP = Trane – Single-Zone Vav Control
w/BACnet w/Display
AR = Trane – Single-Zone Vav Control
w/BACnet (No Display)
BB = Trane – Space Control w/BACnet
(No Display) w/Thumbwheel
BC = Trane – Space Control w/BACnet
w/Display w/Thumbwheel
BG = Trane – Single-Zone Vav Control
w/BACnet w/Display
w/Thumbwheel
BJ = Trane – Single-Zone Vav Control
w/BACnet (No Display)
w/Thumbwheel
CA = Trane – Lab Space Control
w/BACnet (No Display)
CB = Trane – Lab Space Control
w/BACnet w/Display
CC = Trane – Lab Discharge Air Control
w/BACnet (No Display)
CD = Trane – Lab Discharge Air Control
w/BACnet w/Display
CE = Trane – Lab Multi-Zone Vav
Control w/BACnet (No Display)
CF = Trane – Lab Multi-Zone Vav
Control w/BACnet w/Display
CG = Trane – Lab Space Control
w/BACnet (No Display)
w/Thumbwheel
CH = Trane – Lab Space Control
w/BACnet w/Display
w/Thumbwheel
DA = Trane – Horizon Thrive Control
w/BACnet (No Display)
DB = Trane – Horizon Thrive Control
w/BACnet w/Display
XX = Control Special
Digit 27 — Powered Exhaust Fan
Motor (PFM) and Exhaust Dampers
0 = No Powered Exhaust
1 = Direct Drive w/VFD
5 = Special Motor Option
6 = ECM w/Backward Curved Plenum
Fan
7 = ECM w/Backward Curved Plenum
Fan and Barometric Relief Damper
8 = ECM w/Backward Curved Plenum
Fan and Isolation Dampers w/End
switch
9 = Barometric Relief Dampers (No
PFM)\
A = Direct Drive w/VFD and Barometric
Relief Damper
B = Direct Drive w/VFD and Isolation
Dampers w/End Switch
Digit 28 — Powered Exhaust Fan
Wheel
0 = No Powered Exhaust
A = 355
B = 450
C = 450 X 2
D = 12/9 T2 (single fan - belt drive)
E = 12/9 BT (dual fan - belt drive)
F = 315
G = 500
H = 500 X 2
J = 120.6
K = 140.6
L = 100.6
Digit 29 — Powered Exhaust Fan
Motor (hp)
Digit 30 — UC600 Hardware
Template
- = Prior to v8.0
1 = v8.X, v9.X, or v10.X
2 = v11.0 / Thrive v2.1
3 = v11.1 - v11.3 / Thrive v2.1
4 = v12.0 / Thrive v2.2
Digit 31 — ERV (Requires Powered
Exhaust)
0 = No ERV
A = ERV – Composite Construction
w/Bypass
B = ERV – Composite Construction
with Frost Protection w/VFD
C = ERV – Aluminum Construction
w/Bypass
D = ERV – Aluminum Construction with
Frost Protection w/VFD
Digit 32 — ERV Size
0 = No ERV
1 = 3014
2 = 3622
3 = 4136
4 = 4634
5 = 5856
IF ELEC HOT WATER
0 = No Heat No Heat No Heat
A = 50 MBh 5 kW 1 Row/10
FPI
B = 75 MBh 10 kW 1 Row/12
FPI
C = 100 MBh 15 kW 1 Row/14
FPI
D = 125 MBh 20 kW 2 Row/10
FPI
E = 150 MBh 24 kW 2 Row/12
FPI
F = 200 MBh 28 kW 2 Row/14
FPI
G = 250 MBh 32 kW 3 Row/10
FPI
H = 300 MBh 40 kW 3 Row/12
FPI
J = 350 MBh 48 kW 3 Row/14
FPI
K = 400 MBh 60 kW
L = 500 MBh 68 kW
M = 600 MBh 79 kW
N = 99 kW
P = 111 kW
R = 119 kW
X = Special Heater Option
ELEC DF
0 = No Secondary-
Heat
A = 5 kW 6-inch Burner – up
to 330
B = 10 kW 12-inch Burner – up
to 400 MBh
C = 15 kW 12-inch Burner – up
to 600 MBh
D = 20 kW 18-inch Burner – up
to 400 MBh
E = 24 kW 18-inch Burner – up
to 900 MBh
F = 28 kW
G = 32 kW
ECM DIRECT DRIVE
0 = No Powered
Exhaust
A = 1 kW
B = 2 kW
C = 3 kW
D = 4 kW
E = 1 hp – 1800 rpm
F = 1 hp – 3600 rpm
G = 1.5 hp – 1800 rpm
H = 1.5 hp – 3600 rpm
J = 2 hp – 1800 rpm
K = 2 hp – 3600 rpm
L = 3 hp – 1800 rpm
M = 3 hp – 3600 rpm
N = 5 hp – 1800 rpm
P = 5 hp – 3600 rpm