Model Number Descriptions
OAU-SVX007A-EN 17
Digit 33 — Damper Options
0 = 100% OA 2-Position Damper
1 = 100% OA 2-Position Damper
w/RA 2-Position Damper
2 = Modulating OA and RA Dampers
w/Economizer
3 = 100% OA 2-Position Damper –
Class 1A
4 = 100% OA 2-Position Damper w/RA
2-Position Damper – Class 1A
5 = Modulating OA and RA Dampers
w/Economizer – Class 1A
6 = 100% RA Opening (No Damper)
7 = 100% RA w/2-Position Damper
8 = 100% RA w/2-Position Damper –
Class 1A
Digit 34 — Filtration Options
A = No Filters
B = MERV-8, 30%
C = MERV-13, 80%
D = MERV-14, 95%
E = MERV-8 30%, MERV-13 80%
F = MERV-8 30%, MERV-14 95%
G = MERV-8, 30%, with UVC
H = MERV-13, 80%, with UVC
J = MERV-14, 95%, with UVC
K = MERV-8 30%, MERV-13 80%, and
UVC
L = MERV-8 30%, MERV-14 95%, and
UVC
X = Special Filter Options
Digit 35 — Smoke Detector —
Factory Installed
0 = No Smoke Detector
1 = Supply Smoke Detector
2 = Return Smoke Detector
3 = Supply and Return Smoke
Detectors
Digit 36 — Electrical Options
0 = Terminal Block
A = Non-Fused Disconnect
B = Fused Disconnect Switch
C = Non-Fused Disconnect w/
Convenience Outlet
D = Fused Disconnect Switch w/
Convenience Outlet
E = Dual Point Power
F = Dual Point Power w/Convenience
Outlet
G = 65 SCCR Electrical Rating w/Non-
Fused Disconnect
H = 65 SCCR Electrical Rating w/
Fused Disconnect
J = 65 KAIC Electrical Rating w/Non-
Fused Disconnect
K = 65 KAIC Electrical Rating w/Fused
Disconnect
L = 65 KAIC Non-Fused
w/Convenience Outlet
M = 65 KAIC Fused w/Convenience
Outlet
N = 65 SCCR Non-Fused
w/Convenience Outlet
Digit 37 — airflow Monitoring
0 = No Airflow Monitoring
1 = Airflow Monitoring – IFM Piezo
Ring
2 = Airflow Monitoring – PE Piezo Ring
3 = Airflow Monitoring – Outdoor Air
with Display and IFM w/Piezo Ring
4 = Airflow Monitoring – IFM Piezo
Ring and PE Piezo Ring
5 = Airflow Monitoring – OA w/Display
Supply and Exhaust Air w/Piezo
Rings
6 = Airflow Monitoring – Outdoor Air
Monitoring for Direct Fired Heat
Units
Digit 38 — Accessories
0 = No Options
A = Hailguards
B = Hailguards and LED Service Light
in Supply Fan Section
C = LED Service Light in Supply Fan
Section
D = Hailguards and LED Service Light
in Exhaust Fan Section
E = Hailguards and LED Service Light
in Supply and Exhaust Fan Section
F = LED Service Light in Exhaust Fan
Section
G = LED Service Light in Supply and
Exhaust Fan Section
Digit 39 — Altitude
0 = Sea Level to 1,000 feet
1 = 1,001 to 2,000 feet
2 = 2,001 to 3,000 feet
3 = 3,001 to 4,000 feet
4 = 4,001 to 5,000 feet
5 = 5,001 to 6,000 feet
6 = 6,001 to 7,000 feet
7 = Above 7,000 feet