Table 5. Return Duct Connections
Return Ducting General Guidelines
Back returns are not allowed on any S-Series Modular blowers
Side returns are not allowed on downflow or horizontal S-Series Modular blowers
Mounting flanges must be located on ducting
Shoot screws through the mount flanges into the modular blower cabinet
Always seal per local codes and requirements
Modular blower, coil, and ducting must be supported separately
An external overflow drain pan must be installed in all applications over a finished ceiling to prevent property damage
Upflow Modular Blower with Bottom Return in Closet with
Remote Filter
Upflow Modular Blower with Bottom Return in Closet with
Filter Box
Refer to Step 1. Step 2. Step 3. Step 4.
FILTER
Refer to Step 1. Step 5. Step 6. Step 4.
Upflow Modular Blower with Bottom Return Mounted on a
Ducted Pedestal
Upflow Modular Blower with Bottom Return Mounted on a
Ducted Pedestal with Filter Box
Refer to Step 1. Step 7. Step 8. Step 4.
FILTER
Refer to Step 1. Step 9. Step 4.
GGeenneerraall IInnssttaallllaattiioonn