P0V0-SVX001-1A-EN
17
Table 4. Supply Duct Connections (continued)
Horizontal Right and Downflow Modular Blower no Coil
Refer to Step 1. Step 9. Step 4.
IInnssttaallllaattiioonn IInnssttrruuccttiioonnss
1. Bend modular blower flanges up.
2. Set the coil on top of the modular blower.
3. Screw through the coil cabinet into the modular
blower flange. Guide holes are located on the coil.
4. Seal per local codes and requirements.
5. Support the modular blower and coil
independently.
6. Bend modular blower flanges down.
7. Match the coil up flush to the back of the modular
blower.
8. Set the modular blower on top of the coil so that it
is flush with the back of the modular blower.
9. Attach ducting.
GGeenneerraall IInnssttaallllaattiioonn