Maintenance
RTAD-SVX01F-E4
Series R™ Air-Cooled Helical Rotary
Liquid Chiller
RTAD 085 - 180 (50Hz)
Standard, Free Cooling and Heat
Recovery models

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Trane RTAD 100 HE and is the answer not in the manual?

Summary

General Information

General Data - SI Units

Technical specifications for standard RTAD units (SI).

General Data - High Static Pressure

SI specifications for RTAD units with high static pressure.

General Data - English Units

Technical specs for RTAD Standard units (English).

General Data - Low Noise Variants

SI specs for RTAD units with low noise configurations.

General Data - Low Noise with Night Setback

SI specs for low noise RTAD units with night setback.

General Data - High Static Pressure Variants

SI specs for RTAD units with high static pressure.

General Data - Heat Recovery Standard

SI specs for standard heat recovery RTAD units.

General Data - Heat Recovery High Efficiency

SI specs for high efficiency heat recovery RTAD units.

General Data - Heat Recovery Low Noise

SI specs for low noise heat recovery RTAD units.

General Data - Heat Recovery Standard Low Noise

SI specs for standard low noise heat recovery RTAD units.

General Data - Heat Recovery High Efficiency Low Noise

SI specs for high efficiency low noise heat recovery RTAD units.

Installation - Mechanical

Installation Responsibilities

Contractor's duties for proper unit installation.

Installation - Electrical

LonTalk Interface and Network Variables

Overview of LonTalk interface, wiring, and network variables.

Operating Principles

System;Oil Schematic - Standard;PHR

Schematic diagram of system and oil flow for standard/PHR units.

Free-Cooling System Schematic

Schematic diagram illustrating the system for free-cooling units.

Total Heat Recovery System Schematic

Schematic diagram for total heat recovery units.

Pre-Start Checkout

Installation Checklist

Checklist to verify installation completeness before unit startup.

Unit Voltage and Phasing Verification

Verifying supply voltage, imbalance, and phase sequence.

Unit Start-up Procedures

Daily Unit Start-Up Sequence

Describes the sequence of operations for a typical unit startup.

Maintenance

Maintenance Procedures

Refrigerant and Oil Charge Management

Managing refrigerant and oil for unit reliability and performance.

Trane RTAD 100 HE Specifications

General IconGeneral
ModelRTAD 100 HE
RefrigerantR-134a
Cooling Capacity100 tons
Power Supply460V/3/60Hz
Water Flow Rate240 GPM (Typical)

Related product manuals