EasyManua.ls Logo

Trane SEHJ090-162 - Page 7

Trane SEHJ090-162
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RT-SVX24J-EN 7
Model Number Descriptions
DIGIT 18 EXHAUST/RETURN
FAN MOTOR SELECTION
0 None
D 7.5 Hp
E10Hp
F15Hp
G20Hp
H25Hp
J30Hp
K40Hp
L50Hp
M60Hp
DIGIT 19 EXHAUST/RETURN
RPM SELECTION
0 None
3300
4400
5500
6600
7700
8800
9900
A 1000
B1100
C 1200
D 1300
E 1400
DIGIT 20 SYSTEM CONTROL
SELECTION
1 Constant Volume (CV) (Zone
Temperature Control)
2 CV w/ DischargeTemp Control
4 VAV w/ VFD Supply w/o Bypass
(Discharge Temp Control)
5 VAV w/ VFD Supply w/ Bypass
(Discharge Temp Control)
6 VAV Single Zone VAV w/VFD w/o
Bypass (Zone Temperature Control)
7 VAV Single Zone VAV w/VFD w/
Bypass (Zone Temperature Control)
DIGIT 21 OUTSIDE AIR and
ECONOMIZER OPTION/
CONTROLS
A 0-25% Motorized Damper
B Economizer w/Dry Bulb
C Economizer w/Reference
Enthalpy
D Economizer w/Comparative
Enthalpy
E Econ w/TRAQ/DCV/Dry Bulb
1
F Econ w/TRAQ/DCV/Ref
Enthalpy
1
G Econ w/TRAQ/DCV/Comp Enthalpy
1
H Econ w/DCV/Dry Bulb
1
J Econ w/DCV/Ref Enthalpy
1
K Econ w/DCV/Comp Enthalpy
1
1
Requires CO
2
Zone Sensor(s) for DCV to function
DIGIT 22 DAMPER OPTION
0 Standard
1 Low Leak
2 Ultra Low Leak
DIGIT 23— PRE-EVAPORATOR
COIL FILTER SELECTION
0 Two Inch High Efficiency
Throwaway
1 Two InchThrowaway Rack/Less
Filters
2 90-95% Bag Filters w/Prefilters
3 Bag Filter Rack/Less Filters
4 90-95% Cartridge Filters w/
Prefilters
5 Cartridge Rack/Less Filters
6 90-95% Low Pressure Drop
Cartridge Filters w/ Prefilters
7 Low Pressure Drop Cartridge
Rack/Less Filters
DIGIT 24 BLANK SECTION
APPLICATION OPTIONS
0 None
A 90-95% Bag w/Prefilters
B 90-95% Low Pressure Drop
Cartridge w/ Prefilters
C 90-95%, Cartridge Filters w/
Prefilters
D 90-95% High Temp Cartridge
w/ Prefilters
E HEPA w/Prefilters
F HighTemp HEPA w/Prefilters
DIGIT 25 ENERGY RECOVERY
WHEEL
0 None
1 Low CFM ERW w/ Bypass Defrost
2 Standard CFM ERW w/ Bypass
Defrost
DIGIT 26 UNIT MOUNTED
POWER CONNECTION
SELECTION
A Terminal Block
B Non-Fused Disconnect
C Non-Fused Disconnect w/
Powered Convenience Outlet
D Circuit Breaker w/ High Fault SCCR
E Circuit Breaker w/ High Fault SCCR w/
Powered Convenience Outlet
DIGIT 27 CONDENSER COIL
SELECTION
0 Air-Cooled Aluminum
A Evap Condenser
B Evap Condenser w/ Sump Heater
C Evap Condenser w/ Dolphin
WaterCare™System
D Evap Condenser w/ Dolphin
WaterCare™ System & Sump Heater
E Evap Condenser w/ Conductivity
Controller
F Evap Condenser w/ Conductivity
Controller and Sump Heater
J Corrosion Protected Condenser Coil
2
DIGIT 28 EVAPORATOR COIL
AND DRAIN PAN
0 Standard Evap Coil w/Galvanized
Drain Pan
A Standard Evap Coil w/ Stainless
Steel Drain Pan
B High Cap Evap Coil w/Galvanized
Drain Pan
C High Cap Evap Coil w/Stainless
Steel Drain Pan
DIGIT 29 REFRIGERATION
SYSTEM SELECTION A
0 Standard
A Suction Service Valves
B Replaceable Core Liquid Filter
Driers
C Suction Service Valves &
Replaceable Core Liquid Filter
Driers
DIGIT 30 REFRIGERATION
SYSTEM SELECTION B
0 Standard
1 Hot Gas Reheat
3
2 Hot Gas By-Pass
3 Hot Gas Reheat
3
/Hot Gas By-Pass
DIGIT 31 AMBIENT CONTROL
OPTION
0 Standard Ambient
1 Low Ambient
DIGIT 32 HIGH DUCT TEMP
THERMOSTAT
0 None
1 High DuctTempThermostat
DIGIT 33 CONTROLS OPTION
0 None
1 Remote Human Interface (RHI) &
Inter-Processor Communication
Bridge (IPCB)
2 IPCB
3 Rapid Restart
2
Offered on Air-Cooled units
3
Humidity sensor required

Table of Contents

Related product manuals