18-GJ06D2-2A
11
5. Disconnect wires to the EEV motor and sensors. Cut the wire ties on
those wire harnesses if necessary and replace after re-installing.
Note: If cut, wire ties that held the sensor must be replaced after the coil is
placed back into the cabinet.
6. Slide Coil assembly out of unit using built-in coil support channels
and set aside
7. Use a 5/16 Allen wrench on the locking mechanism on each side
of the bottom half of the cabinet to loosen the locking mechanism.
The locks loosen by turning counter-clockwise approximately 3/4
of a turn.
OOppttiioonnaall CCaabbiinneett DDiissaasssseemmbbllyy