System Performance Data
Cooling English Units
TTK512PB WITH MCX512GB
AT 400 CFM
GROSS CAPACITY IN BTU/H x 1000
OUTDOOR I.D. GROSS SENS CAP. AT ENTERING D.B. TEMP. COMPR.
D.B. W.B. CAP. 72 74 76 78 80 kW
61 11.3 8.7 9.4 10.1 10.8 11.3 0.93
85
65 12.2 7.2 7.9 8.7 9.4 10.1 0.97
67 12.7 6.4 7.1 7.9 8.6 9.4 0.99
71 13.6 4.8 5.5 6.3 7.0 7.7 1.03
61 11.0 8.6 9.3 10.0 10.6 11.3* 1.01
95
65 11.9 7.0 7.8 8.5 9.2 10.0 1.05
67 12.3 6.2 7.0 7.7 8.5 9.2 1.07
71 13.2 4.7 5.4 6.1 6.8 7.6 1.11
61 10.5 8.2 9.0 9.7 10.3 10.8* 1.10
105
65 11.4 6.8 7.5 8.2 8.9 9.7 1.14
67 11.8 6.0 6.7 7.4 8.2 8.9 1.16
71 12.7 5.1 5.1 5.8 6.6 7.3 1.21
61 10.1 8.0 8.7 9.4 10.0 10.5* 1.19
115
65 10.9 6.5 7.2 8.0 8.7 9.4 1.23
67 11.3 5.7 6.5 7.2 7.9 8.6 1.26
71 12.2 4.2 4.9 5.6 6.3 7.1 1.30
* Dry coil condition (Gross Capacity = Sensible Capacity)
Gross Capacity and Comp. kW are valid only for Wet Coil
Performance at the Rating Conditions of 80/67 & 95
O
F
GROSS CAPACITY: 12.3 MBH
AIRFLOW: 400 CFM
SYSTEM POWER: 1243 WATTS
NOM. SYSTEM AMPS: 5.7 AMPS
All temperature in Degree F