EasyManua.ls Logo

Trane TTA090A series User Manual

Trane TTA090A series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation
Operation
Maintenance
Split System Cooling Condensers
7 1/2 - 20 Tons
September 2004
Models:
(60 Hz)
TTA090A***F
TTA120A***F
TTA120B***E
TTA120C***G
TTA150B***E
TTA180B***F
TTA180C***G
TTA240B***F
TTA-SVX02C-EN
18-AC60D8-1
(50 Hz)
TTA075AD**F
TTA085AD**F
TTA100AD**F
TTA100BD**E
TTA100CD**G
TTA125BD**E
TTA155BD**F
TTA155CD**G
TTA200BD**F
Question and Answer IconNeed help?

Do you have a question about the Trane TTA090A series and is the answer not in the manual?

Trane TTA090A series Specifications

General IconGeneral
BrandTrane
ModelTTA090A series
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction

Literature Change History

Details revisions made to the manual across different versions.

Overview of Manual

Describes the purpose and scope of the installation, operation, and maintenance manual.

Model Number Description

Split System Condensing Unit Model Nomenclature

Explains the alphanumeric code used to identify specific unit models and their features.

Unit Dimensions

TTA075A, TTA090A Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA085A, TTA100A, TTA120A Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA100B, TTA120B, TTA125B, TTA150B Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA100C, TTA120C Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA155B, TTA180B Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA155C, TTA180C Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

TTA200B, TTA240B Dimensional Data

Provides dimensional data, connection locations, clearances, and corner weights for specific models.

Electrical Data

TTA Unit Electrical Data

Table 3 details electrical characteristics, compressor motor, and outdoor fan motor data for TTA units.

Installation

Installation Checklist

An 'Installation Checklist' is provided at the end of the installation section of this manual.

Unit Inspection and Initial Leak Test

Covers unit inspection for damage, initial leak testing, and clearance checks.

Lifting Recommendations

Provides guidance on safely lifting the unit, considering its weight and center of gravity.

Refrigerant Piping Introduction

Details the need for holes in the structure for running refrigerant lines.

Clearances and Unit Mounting

Details required clearances and methods for mounting units on rooftops or ground.

Refrigerant Piping Guidelines

Maximum recommended line lengths and allowable pressure drops for refrigerant piping are provided.

Recommended Refrigerant Line Sizes

Specifies recommended sizes for suction and liquid refrigerant lines based on unit model and circuit type.

Refrigerant Piping Procedures

Outlines procedures for connecting refrigerant lines to both indoor and outdoor units, including brazing and purging.

Leak Check and System Evacuation

Outlines procedures for leak testing field connections and evacuating the system to a specific micron level.

Refrigerant Charging Procedure

Details the process for charging the system with the correct amount of refrigerant by weight.

Insulating Refrigerant Lines

Provides instructions for insulating suction and liquid refrigerant lines for optimal performance.

Gaseous Charging and Electrical Wiring

Covers gaseous charging procedures and electrical wiring requirements, including unit power supply and disconnects.

Electromechanical Field Wiring

Illustrates typical field wiring diagrams for electromechanical control systems.

Low Voltage Wiring

Details instructions for mounting the indoor thermostat and installing low voltage wiring for system control.

Reliatel Control Field Wiring

Shows typical field wiring connections for the Reliatel control system.

Control System Field Wiring

Details field wiring connections for night setback panels, zone sensors, and thermostats.

Typical Split System Cooling Diagram

Presents a schematic diagram of a typical split system cooling configuration.

System Pre-Start Procedure

Safety Controls

Describes the function of various safety controls within the system.

Pre-Start Installation Checklist

A checklist to verify all installation procedures are complete before system startup.

System Start Procedure (Electro-Mechanical Controls)

Unit Start-Up

Instructions for starting the unit after installation and pre-start procedures.

Sequence of Operation (Electro-Mechanical Controls)

Explains how the system operates in cooling and heating modes using electro-mechanical controls.

Cooling Mode Operation

Details the process of compressor and fan operation during the cooling cycle.

System Start Procedure (ReliaTel™ Controls)

ReliaTel Unit Start-Up

Instructions for starting the unit equipped with ReliaTel controls.

Sequence of Operation ReliaTel™ Control

Explains the operation of the ReliaTel system using microelectronic control algorithms.

ReliaTel Control Cooling Mode

Describes cooling operation based on zone sensor or thermostat inputs for ReliaTel systems.

ReliaTel Control Fan Operation

Details how the evaporator fan operates under ReliaTel control in cooling and heating modes.

ReliaTel Control Heating Operation

Explains how ReliaTel controls manage heating stages and operation.

Service Test Modes (ReliaTel™ Controls)

Test Modes Overview

Describes self-diagnostic checks and methods for testing unit components.

Service Test Guide for Component Operation

Provides a guide to test steps, modes, and resistance values for component operation.

Trouble Shooting (ReliaTel™ Controls)

ReliaTel Control Troubleshooting Guide

Provides diagnostics and status information for troubleshooting ReliaTel control systems.

System Status Checkout Procedure

Details methods for checking system status, including LED indications and voltage readings.

Cooling Failure Diagnosis

Identifies common causes and checks for cooling failures within the system.

Heat/Cool Failure and Lockout Reset

Covers troubleshooting simultaneous heat/cool failures and procedures for resetting lockouts.

System Voltage Checks

Measures voltage between terminals to diagnose system, heat, or cool failures.

Temperature Tests

Procedures for testing zone temperature thermistors and set points.

LED Indicator and Zone Sensor Tests

Describes methods for testing LED indicators and programmable/digital zone sensor functionality.

RTCI Loss of Communications

Explains system behavior when RTCI loses communication with the building management system.

Maintenance

Monthly Maintenance Procedures

Outlines routine monthly inspections and cleaning tasks for unit upkeep.

Annual Cooling Season Maintenance

Details maintenance tasks to be performed at the beginning of each cooling season.

Precautionary and First Aid Measures

Provides safety precautions related to fiberglass insulation and first aid advice.

Maintenance Log

A log sheet for recording inspection data such as temperatures and pressures.

Warranty

Central Air Conditioner Warranty (Parts Only)

Details the warranty terms for central air conditioners, covering parts for the original purchaser.

Commercial Equipment Warranty (Parts Only)

Specifies warranty coverage for commercial equipment rated 20 tons and larger, including related accessories.

Related product manuals