28 UHM-DHM-SF-1H
Service Facts
*DHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
CFM 648 670 681 685 687
Temp. Rise 57 55 54 54 54
Watts 79 79 148 155 219
CFM 676 698 708 711 712
Temp. Rise 54 53 52 52 52
Watts 85 85 156 163 230
CFM 705 725 735 737 736
Temp. Rise 52 51 50 50 50
Watts 93 90 165 170 241
CFM 824 841 849 846 838
Temp. Rise 45 44 43 43 44
Watts 129 119 207 206 291
CFM 923 937 943 936 923
Temp. Rise 55 54 54 54 55
Watts 166 148 249 241 336
CFM 962 974 980 972 956
Temp. Rise 52 52 51 52 53
Watts 183 161 268 256 355
CFM 1001 1012 1017 1008 990
Temp. Rise 50 50 50 50 51
Watts 201 174 288 272 374
CFM 1165 1171 1173 1158 1130
Temp. Rise 43 43 43 44 45
Watts 286 240 382 348 460
CFM 1318 1319 1319 1297 1261
Temp. Rise 53 53 53 54 56
Watts 382 314 485 431 549
CFM 1372 1372 1370 1347 1307
Temp. Rise 51 51 51 52 54
Watts 420 343 526 463 582
CFM 1426 1424 1422 1396 1354
Temp. Rise 49 49 49 50 52
Watts 460 373 569 497 617
CFM 1654 1645 1639 1605 1549
Temp. Rise 42 43 43 44 45
Watts 650 518 770 655 772
Target Airflow
(
See Note 5
)
External Static Pressure
1400
40% (low)
Heat
Low 683
Medium Low 709
Medium** 735
High 845
65%
(medium)
Heat
Low 936
Medium Low 972
Medium** 1008
High 1159
Heating
*DHMB080ACV3VA^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Settin
g
100%
(high)
Heat
Low 1300
Medium Low 1350
Medium**
High 1610
0.1 0.3 0.5 0.7 0.9
CFM 438 436 458 462 474
Temp. Rise 48 48 46 46 45
Watts 26 49 70 90 115
CFM 460 458 479 483 493
Temp. Rise 46 46 44 44 43
Watts 28 52 73 92 118
CFM 499 497 516 518 526
Temp. Rise 42 42 41 41 40
Watts 33 58 79 100 127
CFM 553 551 567 567 571
Temp. Rise 38 38 37 37 37
Watts 42 68 90 114 144
CFM 715 713 720 714 708
Temp. Rise 48 48 48 48 48
Watts 76 106 140 176 217
CFM 753 751 755 749 740
Temp. Rise 46 46 45 46 46
Watts 87 117 154 194 237
CFM 820 818 819 810 797
Temp. Rise 42 42 42 42 43
Watts 108 140 183 228 275
CFM 911 909 904 892 873
Temp. Rise 38 38 38 38 39
Watts 142 177 226 276 326
CFM 906 904 900 888 869
Temp. Rise 58 58 59 59 61
Watts 140 175 223 274 323
CFM 954 952 945 931 910
Temp. Rise 55 55 56 57 58
Watts 160 197 248 300 350
CFM 1041 1039 1027 1010 983
Temp. Rise 51 51 51 52 54
Watts 202 243 295 347 393
CFM 1157 1155 1136 1115 1080
Temp. Rise 46 46 46 47 49
Watts 269 317 361 405 439
Medium Low
Medium**
High
Low
Airflow Setting
*DHMB060BCV3VA^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Target Airflow
(See Note 5)
40% (low) Heat
65% (medium)
Heat
100% (high)
Heat
Low
Medium Low
Medium**
High
Low
Medium Low
Medium**
High
900
950
1040
1160
Heating
External Static Pressure
414
437
478
534
702
741
811
905
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium
heat are percentages of high heat and are not field selectable.