Single Packaged
Heat Pump
Over/Under
2, 2-1/2, 3, 3-1/2, 4, 5 Tons
18-BB33D6-9
Models:
WCH024C1
WCH030C1
WCH036C1
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.
© 2009 Trane
The manufacturer has a policy of continuous product and product data improvement; it
reserves the right to change design and specification without notice.
INSTALLATION
OPERATION
MAINTENANCE
THIS INFORMATION IS FOR USE BY INDIVIDUALS HAVING
ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANI-
CAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL
AIR CONDITIONING PRODUCT MAY RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE. THE MANUFACTURER
OR SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRE-
TATION OF THIS INFORMATION, NOR CAN IT ASSUME ANY
LIABILITY IN CONNECTION WITH ITS USE.
Reconnect all grounding devices.
All parts of this product that are capable of conducting electri-
cal current are grounded. If grounding wires, screws, straps,
clips, nuts, or washers used to complete a path to ground are
removed for service, they must be returned to their original
position and properly fastened.
ALL phases of this installation must comply with NATIONAL,
STATE, and LOCAL CODES.
These instructions do not purport to cover all variations in
systems nor to provide for every possible contingency to be
met in connection with installation. Should further information be
desired or necessary or should particular problems arise which are
not covered sufficiently for the purchaser's or installer's needs or
purposes, the matter should be referred to the manufacturer.
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
CAUTION
!
WARNING
!
CAUTION
!
CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER
HIGH PRESURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING SYSTEM. Failure to follow
proper procedures can result in personal illness or injury or
severe equipment damage.
XE1200
WCH042C1
WCH048F1
WCH060F1
2, 2-1/2, 3, 3-1/2 Tons Shown
Question and Answer IconNeed help?

Do you have a question about the Trane WCH048F1 and is the answer not in the manual?

Trane WCH048F1 Specifications

General IconGeneral
BrandTrane
ModelWCH048F1
CategoryHeat Pump
LanguageEnglish

Summary

Installation Operation Maintenance

Unit Dimensions and Clearances

Installation Applications

Electrical Wiring

Electrical Connections

Wiring and grounding must comply with local codes and NEC.

Disconnect Switch

Install approved weather-proof disconnect on the unit side or nearby.

Over Current Protection

Branch circuit feeding the unit must be protected as shown on the unit rating plate.

Power Wiring

Run power supply lines in conduit, provide strain relief, and flexible conduit supports.

Grounding

Unit must be electrically grounded according to local codes or NEC.

Control Wiring (Class II)

Low voltage control wiring should not run with power wiring unless Class I wire is used.

Start-Up Procedures

Pre-Start Quick Check List

A comprehensive checklist to ensure proper unit setup and safety before starting.

Starting the Unit In the Cooling Mode

Procedure for starting the unit in cooling mode, including crankcase heat operation.

Starting the Unit in the Heating Mode

Procedure for starting the unit in heating mode, ensuring proper settings.

Sequence of Operation

Maintenance

Demand Defrost System

Demand Defrost Control Checkout