Home
Trane
Heat Pump
WSC060-120
Trane WSC060-120 User Manual
4
of 1
of 1 rating
52 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Packaged Heat Pumps
Precedent
™
WSC060-120
50 Hz
PKGP-PRC004-EN
F
ebr
uary 20
04
2
Table of Contents
Introduction
2
Table of Contents
3
Unit Cabinet
4
Easy-Adjust Idler Arm
4
Convertible Units
4
Features and Benefits
4
Standardized Components
5
Easy Access Low Voltage Terminal Board
5
Low Voltage Connections
5
Flexible Applications
5
Micro Controls
6
Reliatel Micro
6
Phase Monitor
7
Factory-Installed Options
7
Economizer
7
Hinged Access Doors
7
Quality and Reliability Testing
8
Varitrac
8
Low Ambient Cooling
9
Barometric Relief
9
Clearance Requirements
9
Application Considerations
9
Cooling Capacity
10
Heating Capacity
10
Selection Procedure
10
Selection Procedure: IP Units
11
Model Number Description
12
General Data
13
Performance Data
14
Gross Cooling Capacities (Kw) WSC060AD,T (SI)
14
Gross Cooling Capacities (MBH) WSC060AD,T (IP)
14
Gross Cooling Capacities (Kw) WSC072AD,T (SI)
15
Gross Cooling Capacities (MBH) WSC072AD,T (IP)
15
Performance Data
15
Gross Cooling Capacities (Kw) WSC090AD,T (SI)
16
Gross Cooling Capacities (MBH) WSC090AD,T (IP)
16
Gross Cooling Capacities (Kw) WSC120AD,T (SI)
17
Gross Cooling Capacities (MBH) WSC120AD,T (IP)
17
Net Heating Capacities (Kw) WSC060AD,T at 3,400 M
18
Net Heating Capacities (MBH) WSC060AD,T at 2,000 CFM (IP)
18
Three Phase Net Heating Capacities (Kw) WSC072AD,T at 4,080 M
19
Three Phase Net Heating Capacities (MBH) WSC072AD,T at 2,400 CFM (IP)
19
Three Phase Net Heating Capacities (Kw) WSC090AD,T at 5,100 M
20
Three Phase Net Heating Capacities (MBH) WSC090AD,T at 3,000 CFM (IP)
20
Three Phase Net Heating Capacities (Kw) WSC120AD,T at 6,800 M
21
Three Phase Net Heating Capacities (MBH) WSC120AD,T at 4,000 CFM (IP)
21
Belt Drive Evaporator Fan Performance WSC060AD,T Downflow Configuration (SI)
22
Belt Drive Evaporator Fan Performance WSC060AD,T Downflow Configuration (IP)
22
Belt Drive Evaporator Fan Performance WSC060AD,T Horizontal Configuration (SI)
23
Belt Drive Evaporator Fan Performance WSC060AD,T Horizontal Configuration (IP)
23
Belt Drive Evaporator Fan Performance WSC072AD,T Downflow Configuration (SI)
24
Belt Drive Evaporator Fan Performance WSC072AD,T Downflow Configuration (IP)
24
Belt Drive Evaporator Fan Performance WSC072AD,T Horizontal Configuration (SI)
25
Belt Drive Evaporator Fan Performance WSC072AD,T Horizontal Configuration (IP)
25
Belt Drive Evaporator Fan Performance WSC090AD,T Downflow Configuration (SI)
26
Belt Drive Evaporator Fan Performance WSC090AD,T Downflow Configuration (IP)
26
Belt Drive Evaporator Fan Performance WSC090AD,T Horizontal Configuration (SI)
27
Belt Drive Evaporator Fan Performance WSC090AD,T Horizontal Configuration (IP)
27
Belt Drive Evaporator Fan Performance WSC0120AD,T Downflow Configuration (SI)
28
Belt Drive Evaporator Fan Performance WSC0120AD,T Downflow Configuration (IP)
28
Belt Drive Evaporator Fan Performance WSC0120AD,T Horizontal Configuration (SI)
29
Belt Drive Evaporator Fan Performance WSC0120AD,T Horizontal Configuration (IP)
29
Over-Sized Motor & Drive Sheave/Fan Speed (RPM)
30
Standard Motor & High Static Drive Accessory Sheave/Fan Speed (RPM)
30
Standard Motor & Sheave/Fan Speed (RPM)
30
Standard Motor & Low Static Drive Accessory Sheave/Fan Speed (RPM)
30
Static Pressure Drops through Accessories - (Pascals)
31
Static Pressure Drops through Accessories - (Inches of Water Column)
31
Auxiliary Electric Heat Capacity
32
Air Temperature Rise Across Electric Heaters (Degrees C)
33
Air Temperature Rise Across Electric Heaters (Degrees F)
33
Field-Installed Control Options
34
Manual Changeover
34
Remote Sensor
34
Controls
34
Unit Wiring
35
Electrical Data
35
Unit Wiring with Electric Heat Single Point Connection — 380–415 Volts
36
Unit Wiring with Electric Heat Single Point Connection — 200 Volts
36
Electrical Characteristics – Evaporator Fan Motor – 50 Hz
37
Electrical Characteristics – Compressor Motor and Condenser Motor – 50 Hz
37
Zone Sensors — Typical Number of Wires
38
Jobsite Connections
38
Downflow Airflow Supply/Return
39
Horizontal Airflow Supply/Return
39
Dimensional Data
39
WSC060 — Downflow Duct Connections — Field Fabricated
40
WSC060 — Roof Curb
40
WSC060 — Unit Clearance and Roof Opening
40
WSC072 and WSC090
41
Wsc120
41
WSC072–120 — Downflow Airflow Supply and Return
42
WSC072–120 — Horizontal Airflow Supply and Return
42
WSC072–120 — Unit Clearance and Roof Opening
42
WSC072–120 — Roof Curb
43
WSC072–120 — Downflow Duct Connections — Field Fabricated
43
Weights
46
Mechanical Specifications
47
Options/Accessories
48
Control Options
49
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Trane WSC060-120 and is the answer not in the manual?
Ask a question
Trane WSC060-120 Specifications
General
Model Number
WSC060-120
Category
Heat Pump
HSPF Rating
9.0
Refrigerant Type
R-410A
Voltage
208/230V
Phase
3
SEER Rating
16
Sound Level
76 dB
Related product manuals
Trane WSC060E
64 pages
Trane WSC036A
64 pages
Trane WSC120A
64 pages
Trane WCC040
28 pages
Trane WCC050
28 pages
Trane WCH024C1
14 pages
Trane WCP036F1
20 pages
Trane WCP-IOM-1E
20 pages
Trane WC*150B***G Series
60 pages
Trane GEHE
118 pages
Trane 2TWR1
8 pages
Trane TWA Series
24 pages