Do you have a question about the Trane WCC030 and is the answer not in the manual?
Details the convertible heat pump unit models available.
Specifies the cooling capacity options in MBh for the units.
Highlights the protection and longevity of the Climatuff® compressor.
Mentions the durable plate fin coil construction for efficiency.
Describes the electronic, time-initiated, temperature-terminated defrost system.
Notes the feature of a sloped drain pan for water management.
Details the use of 100% foil-faced insulation for performance.
Explains the ease of accessing components for diagnosis and replacement.
Refers to the T-Top™ feature for enhanced design.
Highlights the use of screws designed to resist corrosion.
Mentions the application of powder paint for durability.
Describes the water-shedding base for superior water integrity.
States the units offer high operational efficiency.
Explains how units are easily converted between horizontal and downflow configurations.
Details the ease of installation and application flexibility.
Notes low profile horizontal duct take-offs for crawl space applications.
Mentions common cabinets minimizing training and parts inventory.
Highlights flexibility with a single curb fitting multiple models.
Details easy access to electrical components and numbered/color-coded wiring.
Describes features for hassle-free maintenance, like plug-on fan motor.
Notes unit dimensions for shipping and handling, and skid design.
Mentions flush installation and insulation to reduce noise and energy loss.
Highlights smaller cabinets for less intrusive rooftop installations.
Discusses lighter weight components and mounting structure requirements.
Mentions downflow duct flanges preserving water integrity.
Details corrosion resistance through drain pan and cabinet design.
Describes kits for achieving cooling at zero degrees ambient.
Outlines factory testing for coil leaks, pressure, and unit integrity.
States no special thermostats are needed for Impack units.
Describes filter frames accepting standard filters for various configurations.
Details vinyl-coated wire grills protecting the coil.
Explains the universal curb design for quick assembly.
Details the 25% fresh air kit for return air openings.
Mentions adapter kits for duct connections.
Describes a kit for low ambient cooling to 0° F.
Details a solid-state kit for indoor blower delay.
Includes a higher torque indoor fan motor.
Provides reusable lugs for easy unit lifting.
Details a kit for installations with excessive voltage drop.
Explains economizer integration with rain hood and barometric relief.
Describes a kit for enthalpy control with dry/wet bulb sensors.
Details a kit to minimize installation costs for power entry.
Lists available thermostat options for heating and cooling control.
Specifies roof curb options for flat roofs.
Lists manual fresh air damper options for different models.
Details 12" and 14" round duct adapter kits.
Lists 0-100% Modulating Economizer options with barometric relief.
Specifies the 0-100% horizontal economizer option.
Details solid-state enthalpy control options.
Specifies a relay kit for economizer integration.
Lists filter frame kits for different model sizes.
Provides lifting lug kits for unit installation.
Details the low ambient cool kit for evaporator defrost control.
Lists condenser coil guard options for protection.
Specifies high static motor options for fan performance.
Details the anti-short cycle timer accessory.
Lists the indoor fan delay kit.
Breaks down the model number to identify unit characteristics and options.
Provides technical data for units in English units, including ratings and components.
Provides technical data for units in metric units, including ratings and components.
Details cooling performance for WCC030FD00B at 1000 CFM in English units.
Details cooling performance for WCC040FD00B at 1325 CFM in English units.
Details cooling performance for WCC050FD00B at 1675 CFM in English units.
Details cooling performance for WCC030FD00B at 1698 CMH in Metric units.
Details cooling performance for WCC040FD00B at 2250 CMH in Metric units.
Details cooling performance for WCC050FD00B at 2845 CMH in Metric units.
Details heating performance for WCC030FD00B at 1000 CFM in English units.
Details heating performance for WCC040FD00B at 1325 CFM in English units.
Details heating performance for WCC050FD00B at 1675 CFM in English units.
Details heating performance for WCC030FD00B at 0.47 CMS in Metric units.
Details heating performance for WCC040FD00B at 0.63 CMS in Metric units.
Details heating performance for WCC050FD00B at 0.79 CMS in Metric units.
Provides indoor blower performance data for WCC030FD units.
Provides indoor blower performance data for WCC040FD units.
Provides indoor blower performance data for WCC050FD units.
Illustrates the installation of the 25% manual fresh air kit.
Shows a typical filter frame and its components for unit installation.
Details the economizer and rain hood for downflow applications.
Lists available thermostat options for heating and cooling control.
Describes programmable electronic thermostats with 7-day capability.
Outlines options for field-installed control accessories like economizers.
Shows the general field wiring for WCC-F heat pump models.
Illustrates connections for economizer, thermostat, and power entry accessories.
Provides a detailed wiring diagram for WCC030,040,050FD00B units.
Presents the wiring diagram for WCC030,040,050FD00B units with component labels.
Shows the outline and dimensions of the BAYCURB030A roof curb for WCC030F units.
Specifies required unit installation and roof penetration clearances.
Shows the outline and dimensions of the BAYCURB034A roof curb for WCC040,050F units.
Details installation clearances and required roof penetration hole sizes.
Provides dimensions for field fabricated side-by-side ducts for WCC030-050F units.
Illustrates the PVC gasket position on the roof mounting curb for unit placement.
Presents front outline dimensions for WCC030-050F units, including curb compatibility.
Shows front outline drawing dimensions for WCC030-050F units, including conduit knockouts.
Presents rear outline drawing dimensions for WCC030-050F units, including weight distribution.
Covers general unit features, casing, compressor, refrigeration, and fan details.
Details system controls, roof curbs, economizers, and manual air dampers.
Lists available control options including thermostats and programmable features.