Trane WCC030 - General Data - English Units; Unit Specifications (English)

Trane WCC030
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 IPB-99-7-EN-10-6-99
General
Data English Units
MODEL
RATED VOLTS/PH/HZ
A.R.I. RATING
RATINGS (COOLING)
1
BTUH
INDOOR AIR FLOW (CFM)
POWER INPUT (kW)
EER-95 (BTU/WATT-HR.)
6
EER-82
NOISE RATING NO.
2
RATINGS (HEATING)
1
(HIGH TEMP.) BTUH - COP
POWER INPUT (kW)
(LOW TEMP.) BTUH - COP
POWER INPUT (kW)
HSPF (BTU/WATT-HR.)
6
POWER CONNS. — V/PH/HZ
MIN. BRCH. CIR. AMPACITY
3
FUSE SIZE - MAX.(AMPS)
FUSE SIZE - RECMD. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS
L.R. AMPS
BRCH. CIR. SELEC. CUR. AMPS
OUTDOOR COIL — TYPE
ROWS / F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
INDOOR COIL — TYPE
ROWS / F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
DRAIN CONN. SIZE (IN.)
DUCT CONNECTIONS
OUTDOOR FAN — TYPE
NO. USED / DIA. (IN.)
TYPE DRIVE / NO. SPEEDS
CFM @ 0.0 IN. W.G.
4
NO. MOTORS - HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS - L.R. AMPS
INDOOR FAN — TYPE
DIA. X WIDTH (IN.)
NO. USED
DRIVE / SPEEDS (NO.)
CFM VS. IN. W.G.
5
NO. MOTORS - HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS - L.R. AMPS
FILTER — FURNISHED?
TYPE RECOMMENDED
NO. - SIZE - THICKNESS
REFRIGERANT
CHARGE (LBS. OF R-22)
DIMENSIONS
CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.) / NET (LBS.)
WCC030FD00B
380-415/3/50
31000
1000
3.12
9.50
10.90
8.0
29600 - 3.12
2.78
15600 - 2.00
2.29
380-415/3/50
10.2
15
15
CLIMATUFF
®
1 - 1
380-415/3/50
5.7
51
4.2
PLATE FIN
2 / 15
8.62
3/8 COPPER
TXV BLEED
PLATE FIN
3 / 15
3.96
3/8 COPPER
ORIFICE - .071
3/4 FEMALE NPT
SEE OUTLINE DRAWING
PROPELLER
1 / 18
DIRECT / 1
2040
1 - 1/2
900
380-415/1/50
1.7 - 3.8
CENTRIFUGAL
10 X 9
1
DIRECT / 2
SEE FAN PERFORMANCE TABLE
1 - 1/3
900
380-415/1/50
1.1 - 2.6
NO
THROWAWAY
3 - 10 x 25
8.2 LBS.
H X W X D
35-1/4 X 38 X 57
SEE OUTLINE DRAWING
406 / 366
WCC040FD00B
380-415/3/50
39600
1325
4.10
9.70
10.95
8.4
39400 - 3.18
3.66
20700 - 2.06
2.96
6.80
380-415/3/50
13.8
20
20
CLIMATUFF
®
1 -
380-415/3/50
8.0
51
7.1
PLATE FIN
2 / 15
14.0
3/8
TXV BLEED
PLATE FIN
4 / 15
5.4
3/8
ORIFICE- .082
3/4 FEMALE
SEE OUTLINE DRAWING
PROPELLER
1 / 22
DIRECT / 1
2830
1 - 1/2
900
380-415/1/50
1.7 - 3.8
CENTRIFUGAL
11.0 X 11.0
1
DIRECT / 2
SEE FAN PERFORMANCE TABLE
1 - 3/4
900
380-415/1/50
2.1 - 4.8
NO
THROWAWAY
3 - 10 x 25
13.0 LBS
H X W X D
39-3/8 X 47 X 66
SEE OUTLINE DRAWING
561 / 521
WCC050FD00B
380-415/3/50
51600
1675
5.53
9.35
11.15
8.4
53600 - 3.18
4.91
31300 - 2.16
4.21
6.80
380-415/3/50
16.3
25
25
CLIMATUFF
®
1 -
380-415/3/50
9.8
71
10.0
PLATE FIN
2 / 15
14.0
3/8
TXV BLEED
PLATE FIN
4 / 15
5.4
3/8
ORIFICE - .096
3/4 FEMALE
SEE OUTLINE DRAWING
PROPELLER
1 / 22
DIRECT / 1
2830
1 - 1/2
900
380-415/1/50
1.7 - 3.8
CENTRIFUGAL
11.0 X 11.0
1
DIRECT / 2
SEE FAN PERFORMANCE TABLE
1 - 3/4
900
380-415/1/50
2.1 - 4.8
NO
THROWAWAY
3 - 10 x 25
12.0 LBS
H X W X D
39-3/8 X 47 X 66
SEE OUTLINE DRAWING
579 / 539
NOTES:
1
RATED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
2
CALCULATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3
CALCULATED IN ACCORDANCE WITH CURRENTLY PREVAILING NATL. ELECTRIC CODE.
4
STANDARD AIR - DRY COIL - OUTDOOR
5
STANDARD AIR - WET COIL - INDOOR
6
RATED IN ACCORDANCE WITH D.O.E. TEST PROCEDURE. HSPF IS AT THE
MINIMUM DESIGN REQUIREMENT FOR REGION IV.