7
Filter Maintenance
To replace the auxiliary fuel tank lter, remove the cover box to access the
in-line lter and fuel hoses. Be certain that the lter is in the right direction.
Replace the lter with one listed in Filter Replacement Options.
Replacement aer initial installation:
e fuel lter should be replaced within 3 - 6 months. Transfer Flow includes
an extra lter with your initial purchase.
Routine lter replacement:
Transfer Flow recommends the lter be replaced every 12 months on vehicles
that see normal use. If the vehicle is operated in dusty conditions or driven
more than 20,000 miles per year, the lter should be changed every 6 months.
Vehicles traveling outside the United States and Canada may be exposed to
lling stations containing elevated levels of contaminants. It may be wise to
carry spare lters when traveling outside of the country.
Filter Replacement Options:
FRAM G3, WIX 3303, NAPA 23003, TFI 070-FL-32861
NAPA 3270 for cold weather and biodiesel up to B-20
“Critical Failure/Disconnect Power”
If the LCD displays, “CRITICAL FAILURE/DISCONNECT POWER” the user
should deactivate the system by disconnecting the power to the computer
module, located on the top or side of the auxiliary tank. Reference the “TRAX
3™ Computer Module Overview” diagram on page 4; disconnect the three pin
connector with the red and black wire that goes to the TFI wire harness. e
LCD will display, “TRAX 3™ Connecting.....” when the power is disconnected
and the ignition is cycled. e vehicle will now operate from the main tank
only and the main tank gauge will read the fuel level in the main tank just
as though the Transfer Flow system was never installed.
Maintenance and Troubleshooting