EasyManua.ls Logo

Transpak TP-201CE - Grounding Instructions

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-5-
(5) Grounding Instructions Shall Include the Following
This product must be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock. This product is equipped with a cord that has a
grounding wire and an appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
If repair or replacement of the cord or plug is necessary, connect the ground wire to the
ground terminal of the plug. The wire with green insulation (with or without yellow stripes)
is the grounding wire.
Check with a qualified electrician or service person if the grounding instructions are not
clear or if in doubt about the proper grounding of the machine. Do not modify the plug
provided; if it will not fit the power outlet, have the proper outlet installed by a qualified
electrician.
This product is designed for use on a nominal 120 (230) volt AC circuit and has a
grounding plug.
DANGER!
Improper installation of the grounding can result in electrocution.
4. Machine Information
(1) Areas of Application and Machine Description
This plastic strapping machine can be used for a wide range of applications where the
minimum package width is at least 80mm, and the minimum height is 20mm.
This machine is particularly suitable for heavy packaged goods as well as printed products,
boxes, etc.
Machine Description
Semi-automatic plastic strapping machine for use with polypropylene strapping.
Heavy duty construction.
Simple, safe and user-friendly operation.
Moveable, with large table area high capacity strap reel and stainless steel table.
Two locking castors, to ensure safe operation.