19
EN
minipool Phantom PR1
If any alarms appear during initial startup, read the instructions provided in the following table. If the solution is not
possible, immediately contact the Manufacturer to request technical support.
In the meantime, do not try to repair or use the minipool but rather disconnect it from the electricity and water
supplies.
Alarms
ALARMS
NOTIFICATIONS
Screen
displayed
DESCRIPTION OF THE PROBLEM
POSSIBLE SOLUTIONS
HI-43
Temperature
alarm
(notication)
Problem description: if the water temperature in the minipool exceeds
42°C all the functions are deactivated, the display shows the "HI" mes-
sage alternating with the temperature value.
Solutions
: the alarm and the system will automatically reset when the
temperature drops. If the alarm does not reset contact the Manufacturer.
Er
Temperature
sensor alarm
(alarm)
Problem description: a temperature sensor measures the water tem-
perature inside the minipool, activating the heater when necessary.
The allowed water temperatures range from 5°C to 45°C. Values outside
the range cause the blocking of all functions and the permanent activa-
tion of the alarm message.
Solutions:
the alarm will reset automatically once the temperature re-
turns to allowed values (5° to 45°). The message is also displayed if the
temperature sensor malfunctions.
Solutions
: make sure that the water temperature is not outside of the
permitted values, try to disconnect the power supply to the bathtub
and switch it on again after 30 seconds. If the problem persists, verify
that the connection with the control unit is correct and has not been
tampered with. Otherwise contact the Manufacturer.
FLO
No ow alarm
(notication)
Problem description: the notication protects the heater and the
recirculation pump from running in the event of potential danger. It is
activated when the recirculation pump is running, the ow switch does
not detect ow for at least ve seconds. The display shows the message
"FLO" alternating with the temperature, the heater is disabled and the
recirculation pump remains active for a maximum of ve minutes.
Solutions:
the notication will automatically reset when ow is restored,
otherwise a new alarm will be triggered (see FL alarm).
FLC
No ow alarm
(alarm)
Problem description: the alarm is activated in case of ow sensor mal-
functions. The system disables the heater even if the recirculation pump
remains active.
Solutions
: try to disconnect the power supply to the tub and switch it
on again after 30 seconds. If the problem persists, verify that the con-
nection with the control unit is correct and has not been tampered with.
Otherwise contact the Manufacturer.
Fl
Clogged filter
alarm
(alarm)
Problem description: the alarm occurs when, due to lack of ow, the condi-
tion lasts for more than 5 minutes (see "FLO" notication).
The system stops, all functions are disabled and the display shows the xed
"FL" alarm.
The main causes of what has been described are attributable to:
1
Damage to the circulation pump. Once the minipool restarts, verify that
the circulation pump functions correctly.
Solutions:
try to disconnect the power supply to the pool and reconnect
it after thirty seconds; if the problem persists, contact the Manufacturer.
2
excessive dirt on the lter due to incorrect treatment of the minipool
water (see Use and maintenance manual, par. Water treatment on page
37).
Solutions:
disconnect the power supply to the pool and clean the lters.