MAINTAINING THE WATER LEVEL IN THE
MINIPOOL
When the minipool is completely lled a maximum
sensor (SL2) and a minimum sensor (SL1) continuously
monitor the water level inside the compensation tank.
SL1 (minimum sensor) = 0, the sensor does NOT detect
water
SL1 (minimum sensor) = 1, the sensor detects water
SL2 (maximum sensor) = 0, the sensor does NOT detect
water
SL2 (maximum sensor) = 1, the sensor detects water
If the lack of water is minimal (e.g., evaporation or a
person gets out):
The minimum sensor still detects water (SL1 = 1).
The maximum sensor does not detect water (SL2 = 0).
activates automatic lling until conditions are
restored and for a maximum of 60 minutes.
If the lack of water is considerable (e.g., two or more
people get out of the minipool):
Both the minimum and maximum sensors do not
detect water (SL1 = 0, SL2 = 0).
The recirculation pump moves the water from
the compensation tank to the minipool.
The minimum sensor detects water (SL1 = 1, SL2 = 0).
activates automatic lling until conditions are
restored and for a maximum of 60 minutes.
1
MINIPOOL FILLING
Filling is carried out by following the gures on
the side (follow the instructions for your keypad).
Filling takes place from the bottom of the bathtub, and
once it has nished the tank is lled.
After reaching the correct level, the system automatically
stops the lling and makes available the functions of
whirlpool, recirculation, ozone and heater.
At this stage and until lling is completed, no other
functions of the minipool - except chromatherapy - will
be available.
During the lling phase, if the times for reaching the
minimum (90 min) and maximum (60 min) levels in the
overow tank are not met, alarms "AL1" (minimum level)
and "AL2 "(maximum level) will be triggered, stopping
all operation. In this case, you will have to disconnect
the power and restore it after about 30 seconds using
the product's main power switch and check the reason
for this anomaly (leaky pipes, obstructed supply valves,
insufcient pressure).
During the use of the minipool the system automatically
maintains the water level ush with the edge of the
bathtub.
Automatic lling using the keypad pressing the key activates the
automatic lling of the minipool, controlled by two level sensors and
conrmed by the xed blue key.
First run
minipool Phantom SP1