7. Preventive Maintenance
Self-Contained Air Conditioning Unit Preventive Maintenance
Note: The following pages can be photocopied for use during scheduled maintenance. Tripp Lite recommends that completed maintenance
forms be saved for future reference.
Tripp Lite SRCOOL33K/SRXCOOL33K MONTHLY MAINTENANCE CHECKLIST
Prepared By: __________________________________________________________________Date:______________________________________
Model Number_________________________________________________Serial Number______________________________________________
General Inspection
Location of cooling unit____________________________________________________________________________________________________
Temperature setpoint______________________________________________________________________________________________________
Room temperature/humidity near the return of the cooling unit:
Temperature _________________Humidity _________________
Is the unit maintaining the temperature setpoint? Yes q No q
Is there visible damage to the cooling unit, e.g. dents or scratches? Yes q (Specify) No q
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
Are there indications of environmental damage (dirt, dust, debris, liquid stains) around the unit installation area?
Yes q (Specify) No q
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
Previous month’s alarm history:
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
Cleanliness Inspection
q Check the condition of return air filters. Change if necessary.
Mechanical/Electrical Inspection
Caution!
Turn off the cooling unit and disconnect all power sources before performing mechanical and electrical checks.
q Check the fan. All components should be moving freely, with no indication of binding or damage.
q Verify that the condensate line is flowing freely.
q Inspect the power cord and plug for damage.