EN Operating manual – Oil heater IDE 20 / IDE 30 / IDE 50 / IDE 60 / IDE 80 3
Fuels
The following fuels are approved for the oil heaters IDE 20 / IDE
30 / IDE 50 / IDE 60 / IDE 80: EL fuel oil, diesel
Technical data
Type IDE 20 IDE 30 IDE 50 IDE 60 IDE 80
Article number 1,430,000,215 1,430,000,220 1,430,000,230 1,430,000,235 1,430,000,240
Parameter Value Value Value Value Value
Mains connection 1/N/PE~ 230 V 50 Hz
Current consumption 0.8 A 1.5 A 3.2 A 3.7 A 3.7 A
Heating capacity nom. 20 kW 30 kW 50 kW 60 kW 80 kW
Air volume flow 600 m³/h 760 m³/h 2000 m³/h 2000 m³/h 2000 m³/h
Fan axial axial axial axial axial
Temperature increase ΔT 85 °C 80 °C 95 °C 75 °C 90 °C
Fuel consumption 1.6 l/h 3.4 l/h 4.6 l/h 5.2 l/h 7.8 l/h
Tank contents 24 l 50 l 68 l 68 l 68 l
Chimney connection ø 120 mm ø 120 mm ø 150 mm ø 150 mm ø 150 mm
Thermostat connection series series series series series
Combustion indirect indirect indirect indirect indirect
Noise level (distance 1 m) 65 dB(A) 75 dB(A) 75 dB(A) 85 dB(A) 85 dB(A)
Length 835 mm 1,075 mm 1,370 mm 1,275 mm 1,275 mm
Width 360 mm 445 mm 560 mm 505 mm 505 mm
Height 515 mm 565 mm 995 mm 795 mm 795 mm
Weight 20.9 kg 34.6 kg 59.5 kg 59.5 kg 59.4 kg