17 EN
Operating manual – local air conditioner PAC 2010 E / PAC 2610 E
Error codes
The following error messages can be displayed on the segment
display(13):
Error code Cause Remedy
F0 Leaking cooling agent Disconnect the device from the
mains for approx. 30min.
Should the error still be displayed
after the restart, please contact
the customer service.
System blocked
F1 Defective room
temperature sensor
Please contact the customer
service.
F2 Defective temperature
sensor of evaporator
F4 Defective exhaust air
temperature sensor
H3 Tripped overload
protection of compressor
Check whether the ambient
conditions are outside the range
specified in the technical data.
Wait until temperature and
humidity level are back within the
operating range before switching
the device back on.
Check whether air inlet and outlet
are obstructed by any objects and
remove these before switching
the device back on.
Should the error still be displayed,
please contact the customer
service.
E8 Malfunction due to
overload
H8 Condensation tank full Discharge condensate (manual
draining) according to the
Maintenance chapter.