10 EN
dehumidifier TTK 120 E / TTK 122 E
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.
ü The supplied hose(diameter=16mm) and the metal clamp
are ready for use.
ü The device is switched off.
1. Remove the condensation tank.
ð Make sure not to damage the float when removing the
condensation tank.
2. Push one end of the hose onto the hose connection.
3. Secure the end of the hose with a metal clamp.
4. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
ð The device can now be switched on.
Automatic defrost by means of hot gas feed
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device then carries out an
automatic defrost by means of the hot gas feed. Here, a hot
cooling agent is led into the iced evaporator for its surfaces to
defrost.
The hot gas automatic defrost system integrated in the device
automatically switches on the defrost cycle at regular intervals.
The automatic defrost LED(16) is illuminated throughout the
defrost process.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.