Operating Manual Notes

Understanding Warning Symbols

Explains various warning symbols and their meanings for safe operation.

General Safety Precautions

Safe Usage and Hazard Avoidance

Key rules for operating the appliance safely and preventing hazards.

Emergency Procedures and Device Overview

Emergency Behaviour

Steps to take and precautions during an emergency situation.

Device Description and Depiction

Explains the device's principle, parts, and provides a visual diagram.

Transport, Storage, and Assembly

Transport and Storage Guidelines

Instructions for safely moving and storing the dehumidifier.

Assembly and Installation Steps

Includes scope of delivery, unpacking, and mounting the wheels.

Device Start-up Procedures

Positioning and Connections

Guidance on placing the device, maintaining distances, and connecting power.

Filter and Tank Installation

Instructions for installing the air filter and condensation tank.

Device Operation Controls

Operating Elements Overview

Details on all buttons, LEDs, and displays on the control panel.

Basic Operation Controls

How to switch on, set humidity, and adjust fan speed.

Timer and Continuous Modes

Instructions for using the timer function and continuous operation mode.

Advanced Operation Features

Automatic Timer Functions

Setting automatic switch-on and switch-off timers for convenience.

Specialized Operation Modes

Includes automatic defrost, drying laundry, and hose connection.

Shutdown and Troubleshooting

Safe Shutdown Procedure

Important safety precautions for turning off and disconnecting the device.

Common Errors and Faults

Troubleshooting steps for issues like device not starting or no condensate.

Further Troubleshooting

Compressor and Performance Issues

Addressing problems with the compressor not starting or device performance.

Contacting Support

Guidance on seeking professional help for unresolved operational issues.

Maintenance Schedule and Log

Maintenance Intervals

Table outlining the recommended frequency for various maintenance tasks.

Maintenance and Care Log

A log to record performed maintenance and care activities.

Maintenance Preparations and Cleaning

Pre-Maintenance Safety

Essential electrical safety steps to follow before performing any maintenance.

Cleaning Components

Instructions for cleaning the housing and the air filter.

Condensation Tank Management

Emptying and Cleaning the Tank

Procedure for emptying and cleaning the condensation tank when it is full.

Technical Specifications and Post-Maintenance

Technical Data Overview

Detailed specifications of the dehumidifier, including performance and dimensions.

Post-Maintenance Procedures

Steps to take after maintenance before resuming operation.

Product Disposal Information

Overview

This document describes the Trotec TTK 65 E dehumidifier, an appliance designed for drying and dehumidifying room air. It operates on the principle of condensation, making it suitable for various indoor environments such as living rooms, bedrooms, bathrooms, basements, laundries, holiday homes, camper vans, and boats. It can also be used for maintaining dryness in storage spaces, archives, laboratories, garages, washrooms, and changing rooms. Additionally, the device can function as a clothes dryer for wet laundry.

Function Description

The TTK 65 E dehumidifier works by drawing damp room air through an air inlet and an air filter. The air then passes over a cold evaporator, where it is cooled below its dew point. As a result, water vapor in the air condenses on the evaporator fins, forming condensation or rime. The dehumidified, cooled air is then slightly warmed by a condenser and blown out of the device. This drier, conditioned air mixes with the room air, continuously reducing the overall humidity.

The condensed water either drips continuously or during a defrost phase into an integrated drain nozzle, collecting in a condensation tank located below. The tank is equipped with a float mechanism to measure the filling level. When the condensation tank reaches its maximum capacity or is not correctly installed, a dedicated indicator light on the control panel illuminates, and the device automatically switches off. Operation resumes once the emptied condensation tank is reinserted.

For continuous operation or unattended dehumidification, a condensation drain hose can be attached to the device, allowing the collected water to be drained directly. The device can reduce relative room humidity to approximately 30%. Due to the heat generated during operation, the room temperature may rise slightly.

The device features an automatic defrost function. At low ambient temperatures, ice may form on the evaporator. During defrosting, dehumidification is temporarily interrupted, but the fan continues to run. It is important not to switch off the device or remove the mains plug during automatic defrost.

A memory function ensures that the selected target value for relative room humidity is saved after a brief power failure. However, any activated timer settings will not be retained.

Usage Features

The TTK 65 E is designed for ease of use and portability. It is equipped with a carry handle and wheels for convenient transport.

Control Panel: The device is operated via a control panel with several buttons and LED indicators:

  • ON/OFF button (17): Switches the device on or off.
  • +/- button (18): Used to set the desired relative room humidity in 5% increments, ranging from 35% to 80%.
  • FAN SPEED button (19): Adjusts the fan speed to LOW, MID, or HIGH, indicated by corresponding LEDs (10).
  • TIMER button (20): Activates the automatic switch-on or switch-off timer function for 2 or 4 hours, indicated by TIMER LEDs (9).
  • POWER LED (12): Illuminates when the device is running.
  • BUCKET FULL LED (13): Flashes when the condensation tank is full or not correctly inserted.
  • FILTER RESET LED (14): Illuminates when the air filter needs cleaning.
  • CONTINUOUS LED (15): Illuminates during continuous operation mode.

Operating Modes:

  • Automatic Dehumidification: After switching on, the device operates automatically. The fan runs continuously until the set nominal humidity value is reached or the device is switched off.
  • Setting Desired Humidity: Users can preselect the desired relative room humidity using the +/- button.
  • Setting Fan Speed: The fan speed can be adjusted to LOW, MID, or HIGH.
  • Continuous Operation: In this mode, the device dehumidifies constantly, regardless of the relative room humidity. The relative humidity and fan speed cannot be set in this mode. The device operates at its highest dehumidification performance until the condensation tank is full or, if a drain hose is used, until the device is switched off.
  • Timer Function: The timer allows for automatic switch-on or switch-off after a preset number of hours (2 or 4 hours).

Condensate Drainage:

  • Condensation Tank: The collected condensate is stored in a removable tank. This tank should be emptied when the BUCKET FULL LED flashes.
  • Continuous Drain Hose: For continuous operation, a hose (12 mm diameter) can be connected to the device's condensation drain hose connection, allowing water to drain directly into a suitable container or drain.

Drying Laundry: When used as a clothes dryer, specific relative humidity values are recommended:

  • Cupboard dry: 46% relative humidity
  • Iron dry: 58% relative humidity
  • Slightly dried: 65% relative humidity A measuring device can be used to determine the humidity level if necessary.

Safety Instructions: Users must read and understand the operating manual, especially the Safety chapter, before using the device. Key safety points include:

  • Do not use the device in potentially explosive rooms or aggressive atmospheres.
  • Set the device up in an upright and stable position.
  • Do not operate the device with wet or damp hands or when it is wet from cleaning.
  • Avoid direct water spray.
  • Never insert objects or limbs into the device.
  • Do not cover or transport the device during operation.
  • Do not sit on the device.
  • Keep the device away from children and animals.
  • Check accessories and connection parts for damage before each use.
  • Ensure all electric cables are protected from damage.
  • The electrical connection must match the specifications in the Technical data chapter.
  • Insert the mains plug into a properly secured mains socket.
  • Completely unroll extension cables and avoid electrical overload.
  • Disconnect the device from the mains before maintenance, care, or repair work.
  • Do not use the device if the mains plug or power cable is damaged.
  • Observe minimum distances from walls and objects as specified in the Technical data.
  • Ensure air inlet and outlet are not obstructed and free of dirt.
  • Do not remove safety signs, stickers, or labels.
  • Transport the device only in an upright position with an emptied condensation tank or drain hose.
  • Discharge collected condensate before transport and storage; do not drink it.

Maintenance Features

Regular maintenance ensures the device's optimal performance and longevity.

Before Starting Maintenance:

  • Switch off the device and remove the mains plug from the socket.
  • Do not touch the mains plug with wet or damp hands.
  • Tasks requiring the housing to be opened must only be performed by authorized specialist companies or Trotec.

Cleaning the Housing:

  • Clean the housing with a soft, damp, lint-free cloth.
  • Ensure no moisture enters the housing and protect electrical components.
  • Do not use aggressive cleaning agents such as sprays, solvents, alcohol-based, or abrasive cleaners.

Visual Inspection of the Inside:

  • Remove the air filter.
  • Use a torch to check the inside of the device for dirt.
  • If a thick layer of dust is present, have the inside cleaned by a specialist company for cooling and air-conditioning or by Trotec.
  • Reinsert the air filter.

Cleaning the Air Filter:

  • The air filter must be cleaned when dirt is visible or when the FILTER RESET LED (14) lights up.
  • Remove both the air filter and the additional filter located behind it.
  • Clean both filters with a slightly damp, soft, lint-free cloth. For heavy contamination, use warm water mixed with a neutral cleaning agent.
  • Allow the filters to dry completely before reinserting them.
  • Ensure the air filter is not worn, damaged, or deformed.
  • After cleaning, switch the device on and press the FILTER button (16) to reset the FILTER RESET LED.

Emptying the Condensation Tank:

  • When the condensation tank is full or incorrectly inserted, the device stops dehumidification. The BUCKET FULL LED (13) flashes.
  • Remove the condensation tank from the device.
  • Empty the tank over a drain or sink.
  • Rinse the tank with clear water and clean it regularly with a mild cleaning agent (no detergent).
  • Refit the condensation tank, ensuring the float is positioned correctly and not damaged.

Refrigerant Circuit:

  • The entire refrigerant circuit is a maintenance-free, hermetically sealed system.
  • Maintenance or repair of the refrigerant circuit must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

After Maintenance:

  • If continuing to use the device, allow it to rest for 12 to 24 hours for the refrigerant to accumulate within the compressor before switching it back on. Failure to do so may lead to compressor damage and void warranty claims.
  • Reconnect the device to the mains.
  • If storing the device for a considerable time, follow the Storage chapter guidelines.

Trotec TTK 65 E Specifications

General IconGeneral
Dehumidification capacity20 l/24h
Operating temperature range5 - 35 °C
RefrigerantR290
GWP factor3
Working range humidity30 to 80 % RH
Input voltage220-240 V
Dimensions (L x W x H)250 x 320 x 500 mm

Related product manuals