EN 15
dehumidifier TTK 75 E
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter Value
Model TTK75E
Max. dehumidification
performance
20l/ 24h
Air flow rate 150m
3
/h max.
Operating range (temperature) 5 °C to 32 °C
Operating range (relative
humidity)
30% to 90%RH
Pressure suction side 1.2MPa
Pressure outlet side 2.4MPa
Max. permissible pressure 2.6MPa
Mains supply 220 – 240V ~ 50Hz
Max. power consumption 420W
Nominal current 1.8A
Fusing
T1 A/250 V
Type of protection IPX0
Refrigerant R290
Amount of refrigerant 86g
GWP factor 3
CO
2
equivalent 0.000258t
Water tank 3 l
Sound pressure level 43 dB(A)
Dimensions (lengthx widthx
height)
245x 340x 570mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
45 cm
45 cm
45 cm
45 cm
Weight 12.5kg