EN 13
dehumidifier TTK 96 E / TTK 127 E
The compressor does not start:
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check whether the device is running in comfort mode.
In this case, the compressor switches off automatically
once the relative room humidity is below 45%.
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or is losing
performance:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error codes can be displayed:
Error code Cause Remedy
AS Error humidity sensor Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
ES Error at the
temperature sensor
of the evaporator
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
P2 Condensation tank
full or not inserted
correctly
Empty the condensation
tank or check the
condensation tank for
correct fit.
EC Leakage in the
refrigerant circuit
Switch the device off and
contact the customer
service. Also see the
information regarding the
refrigerant circuit in chapter
Maintenance.
E3 General fault at the
device
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.