Manual of Operation and Instruction
M
M
o
o
d
d
e
e
l
l
3
3
2
2
4
4
1
1
S
S
e
e
r
r
i
i
e
e
s
s
A
A
s
s
p
p
h
h
a
a
l
l
t
t
C
C
o
o
n
n
t
t
e
e
n
n
t
t
G
G
a
a
u
u
g
g
e
e
s
s
Troxler Electronic Laboratories, Inc.
3008 E. Cornwallis Road P.O. Box 12057
Research Triangle Park, NC 27709 U.S.A.
Phone: 1.877.TROXLER
Outside the U.S.A.: +1.919.549.8661
Fax: +1.919.549.0761
www.troxlerlabs.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Troxler 3241-C and is the answer not in the manual?

Troxler 3241-C Specifications

General IconGeneral
BrandTroxler
Model3241-C
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 3: Operating the Gauge

First-time setup

Initial steps for setting up the gauge after unpacking.

Taking Background Counts

Procedure for establishing a baseline measurement to adjust for environmental factors.

Taking a Measurement

The process of performing a measurement of asphalt content.

Chapter 4: Calibrations

Preparing Calibration Samples

Detailed steps for creating accurate calibration samples.

Performing the Calibration

Step-by-step guide to calibrating the gauge with prepared samples.

Chapter 5: Projects

Chapter 6: Shift Functions

Slope Offset

Adjusting calibration slope when source asphalt changes.

Relative Offset (%AC Shift)

Correlating gauge readings with extraction results.

Relative Offset (Intercept)

Adjusting calibration intercept due to aggregate moisture changes.

Slope/Intercept Offset

Adjusting calibration curve slope and intercept for sample gradation changes.

Calibration Sample Preparation

Function to enter calibration values and assist in sample preparation.

Chapter 7: Special Functions

Stat Test

Validating normal operation by performing a series of short counts.

Drift Test

Checking for long-term drift in gauge readings after a stat test.

Calibration Transfer

Transferring calibrations from a master gauge to field gauges.

Cross Calibration

Establishing a relationship between master and field gauges.

Appendix A: Radiological Information

Radiation Safety

General safety practices and precautions for working with radioactive materials.

Limiting Exposure

Methods to minimize radiation exposure (time, distance, shielding).

Appendix C: Maintenance & Troubleshooting

Troubleshooting

Guidance for diagnosing and resolving common gauge issues.

Gauge Fails Self-Test (He3 Tube Error)

Specific steps to address self-test failures related to He3 tubes.

Gauge Does Not Turn “On”

Troubleshooting steps for a gauge that fails to power on.

Control Unit Displays “Gauge Too Hot” Error

Steps to resolve overheating errors displayed by the control unit.

Gauge Readings are not Accurate

Procedures to follow when the gauge provides incorrect or fluctuating readings.

Gauge Appears to be Unstable

Steps to take if the gauge's performance is inconsistent.

Leak Testing

Procedure for testing the integrity of the radioactive source encapsulation.