CS800/LC900 Bike
1. Disconnect the console data cable on the upper panel. If there is
still full resistance, continue to the next step. If the full resistance
condition subsides, replace upper console.
2. Disconnect the console cable on the lower controller and retest for
full resistance.
3. If full resistance stops, replace the console cable.
4. If full resistance continues, disconnect the generator cable on the
controller and retest for full resistance.
5. If full resistance stops, replace the controller.
6. If full resistance continues, disconnect the generator cable from the
generator assembly.
7. If full resistance stops, replace the generator cable.
8. If full resistance continues, replace the generator assembly.
7
Full Resistance
When Pedaling
Begins