True Food Service Equipment, Inc.
11
11
INSTALLATION / OPERATION INSTRUCTIONS
A. Beforeyournewunitisconnectedtoapowersupply,
checktheincomingvoltagewithavoltmeter.Ifanything
lessthan100%oftheratedvoltageforoperationisnoted,
correctimmediately.
B. Allunitsareequippedwithaservicecord,andmustbe
poweredatproperoperatingvoltageatalltimes.Referto
cabinetdataplateforthisvoltage.
TRUErequires that a sole use circuit be dedicated for the unit.
Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor burns out due to
low voltage.
WARNING
Power supply cord ground should not be removed!
WARNING
Do not use electrical appliances inside the food storage
compartments of the appliances unless they are of the
type recommended by the manufacturer.
NOTE
To reference wiring diagram - Remove front louvered grill, wiring
diagram is positioned on the inside cabinet wall.
ELECTRICAL INSTRUCTIONS
Step 1 - Position Cabinet
AllowoneinchbetweenthewallandrearoftheGDM
refrigeratortoassureproperventilation.ForGDMfreezers
3inchesbetweenthewallandrearofthecabinetwillassure
properventilation.
Step 2 - Level Cabinet
Cabinetshouldbelevel,sidetosideandfronttoback.Placea
carpenter’slevelintheinteriorfloorinfourplaces:
A. Positionlevelintheinsideflooroftheunitnearthe
doors.(Levelshouldbeparalleltocabinetfront).Level
cabinet.
B. Positionlevelattheinsiderearofcabinet.(Againlevel
shouldbeplacedparalleltocabinetback).
C. Performsimilarprocedurestostepsa&bbyplacingthe
leveloninsidefloor(leftandrightsides-paralleltothe
depthofthecooler).Levelcabinet.
Step 3
Drawanoutlineonthebaseonthefloor.
Step 4
Raiseandblockthefrontsideofthecabinet.
Step 5
Applyabeadof“NSFApprovedSealant”,(seelistbelow),To
flooronhalfinchinsidetheoutlinedrawn.Thebeadmust
beheavyenoughtosealtheentirecabinetsurfacewhenitis
downonthesealant.
Step 6
Raiseandblocktherearofthecabinet.
Step 7
ApplysealantonfloorasoutlineinStep5.onotherthree
sides.
Step 8
Examinetoseethatcabinetissealedtoflooraroundentire
perimeter.
Note
Asphalt floors are very susceptible to chemical attack.
A layer of tape on the floor prior to applying the sealant
will protect the floor.
NSF Approved Sealants:
1.MinnesotaMining#ECU800Caulk
2.MinnesotaMining#ECU2185Caulk
3.MinnesotaMining#ECU1055Bead
4.MinnesotaMining#ECU1202Bead
5.ArmstrongCork-RubberCaulk
6.ProductsResearchCo.#5000RubberCaulk
7.G.E.SiliconeSealer
8.DowCorningSiliconeSealer
SEALING CABINET TO FLOOR