12
Electrical connection 230 / 240 V
– option –
The electrical connection is only to be carried out by a
licensed electrician. The information given here is not
intended as information for the layman, rather it is to for
assisting the assigned electrician, as additional information,
when connecting the appliance!
The electric heating element in the water heater is supplied
with a mains cable and fitted 3-pole, earthed plug (in compli-
ance with the norm AS/NZS 3112/2000)
Fig.21
In order to operate the element the manufacturer of the vehi-
cle has to supply and install a socket with switch (2-pole sep-
aration) which is approved in Australia and earthed.
All cables must be secured with cable clips.
Cables must be in accordance with the technical rules and
regulations of the country in which the vehicle is to be
registered, for the first time.
Function check
After installation, check gas supply line for leaks in accord-
ance with the pressure drop method. Following this, check
the function of the appliance as specified in the operating
instructions, check the function of the draining of the water
contents, in particular. There shall be no claims under
guarantee for damage caused by frost!
Never operate the water heater without water contents.
It is, however, possible to briefly check the electrical function
without water contents. Always observe the operating instruc-
tions prior to operation!
The operating instructions and completed guarantee card are
to be given to the owner of the vehicle.
Warning information
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to all
users (e. g. on the wardrobe door)! Ask Dometic to send you
stickers, if necessary.
Accessories
Safety/drain valve and water connectors for flexible
water hoses
34150-01 Hot water connector, 10 mm / 3/8"
70150-01 Cold water connector, 10 mm / 3/8"
70141-02 Safety/drain valve (280 kPa), 10 mm / 3/8"
Fig.22
Cowl extension for wall thicknesses over 35 mm
70131-00 Cowl extension VBO 2
Fig.23
Control panel extension cable
70000-53500 Control extension cable 5 m
Fig.24

Other manuals for Truma B 10