Technical data
determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Protection class
IP21
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Gas type
Liquid gas (propane/butane)
Operating pressure
30 mbar
Nominal heat load
Q
n
= 1.5 kW (H
i
); 120 g/h; C
11
; I
3B/P(30)
Heating time from approx. 15°C to approx. 70°C
Gas mode: approx. 31 min.
Electrical mode: approx. 29min. (BGE 10)
Gas and electrical mode: approx. 16min. (BGE 10)
Power supply
12V
230 V / 50 Hz
Power consumption at 12V
Ignition: 0.16 A
Heating: 0.12 A
Standby: 0.05 A
Power consumption at 230 V (Boiler gas/electric)
Heating: (3.7 A) 850 W / (5.7 A) 1300 W
Standby – gas consumption
approx. 70W
Weight without water
(Boiler gas)
6.9kg
(Boiler gas/electric)
7.4 kg
Destination countries
AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HR,
HU, IE, IS, IT, LI, LT, LU, LV, MT, NL, NO, PL, PT, RO, SE, SI,
SK, TR
E1 10R-05 2604
Subject to technical changes.
Dimensions
Water
connections
Gas connector
Electronics
Cutout
Cowl
Cutout
245
129
261
168
47
30
360
347
383
92
109
24
Figure 6 – All dimensions in mm.
7