Fault Cause Remedy
Gas mode
Boiler does not operate after
switching on.
No 12 V
power supply.
Window open.
Check the battery voltage (min. operating voltage 10.5V ).
Check boiler fuse
(see Maintenance, “Fuses”).
Close window above cowl.
After switching on, boiler does
not operate and red LED comes
on after about 30 sec.
After a long period of operation,
boiler switches to “Fault” and
red LED comes on.
Cowl cover is fitted.
No gas supply.
Incorrect gas pressure.
Air in gas supply.
Overtemperature sensor
has activated.
Remove cowl cover and/or check for soiling and remove
if necessary.
Check gas valves and cylinder.
Check gas valves and cylinder.
To clear the fault (and bleed off air), switch the appliance
off, wait for 5minutes and switch it on again.
Check the water content, topping up if necessary (close
drain valve).
To clear the fault, switch the appliance off, wait for 5 min-
utes and switch it on again.
Electrical mode (BGE 10)
Boiler does not operate
after switching on.
No 230 V power supply.
Overtemperature sensor
has activated.
Heats up too slowly
with switch set to 850W.
Connect vehicle to the local central power supply and/or
check residual current protective device.
Check the water content, topping up if necessary (close
drain valve).
The electric heating element is fitted with an overtemper-
ature sensor. In the event of a fault, switch off at the con-
trol panel, wait for 10minutes, then switch on again.
Please contact Truma Service.
Water supply
Water dripping from drain
valve.
Warm water coming out of cold
water tap.
Water pressure too high.
Hot water flowing
back into cold water
supply.
Check water pressure (max. 2.8bar). When connecting to
a central water supply a pressure reducer must be used.
Fit a non-return valve to the cold water supply
(see installation instructions, “Water connection”).
If these actions do not remedy the problem, please contact Truma Service.
Troubleshooting guide
8

Other manuals for Truma BGE 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma BGE 10 and is the answer not in the manual?

Truma BGE 10 Specifications

General IconGeneral
BrandTruma
ModelBGE 10
CategoryBoiler
LanguageEnglish

Related product manuals