15
3 Communication between the PC and the device.
– Field flashes green – faulty communication.
– Field shines red – interruption.
Show error detail
Any errors are marked in red on the screen.
1 Show the error details
by clicking the field
marked in red.
or
2 Show the error details
by clicking the “Error”
tab.
3 Detailed description of
the error.
4 Return to the
“Live Display” pro-
gram by clicking the
“Live Display” tab.
Set operating status
Certain operating parameters can be set for examinations.
For the Combi 4 (E) / Combi 6 (E) devices this is e.g. the field
“Burner” or “ULMotor”. If the cursor is moved over this field,
the cursor changes from an arrow to a hand.
Combi 4 (E) / Combi 6 (E)
1 Click the field
“Burner” to change
the parameters of the
burner.
Set the speed of
the “ULMotor”
(D.C motor) to min.
25 % otherwise the
heater may cut out
due to overheating.
or
2 Click the field
“ULMotor” to change
the parameters of the
D.C. motor.
End program
1 Open the menu “File”
and leave the program
by pressing “End”.
Disconnect the diag-
nosis cable from the
test object.
Switch device off.
–
–
“Live Display” program
Show or change the operating statuses and parameters
Prerequisites for operation:
Device from index
Combi 4 (E)
Combi 6 (E)
4/12A 6/12A
4/11 6/11
4/12 6/12
4/13 6/13
Combi D –
Mover® –
Start program
The “Diagnose Tool” program may not be active, it
must be closed first.
Combi 4 (E), 6 (E): Operate the device in heating mode with
the D.C. motor due to overheating. To do this, set the rotary
knob for the room temperature to “5” on the control panel.
1 Double-click the icon
on the desktop.
or
2 A start screen is shown
whilst the program is
loading.
Search for device
1 Open the “Tools”
menu and click “Start”
to start the search.
After a successful search, this screen is shown with param-
eters in the case of a Combi.
Display the current action
1 Device search.
2 Initialisation of the hardware and software.