Improper operation or operation contrary to operating or installa-
tion instructions, particularly any disregard for maintenance, care
or warning notes,
Instances where installations, repairs or any other procedures have
been conducted by non-authorised parties
Consumable materials and parts which are subject to natural wear
and tear
Installation of replacement, supplementary or accessory parts
that are not original manufacturer’s parts or which have not been
approved by the manufacturer. This applies in particular if the ap-
pliance is subject to networked control, if the control units or the
software have not been approved by Truma or if the Truma control
unit (e.g. Truma CP plus or Truma iNet Box) has not been exclusive-
ly used for controlling Truma appliances or appliances approved by
Truma.
As a consequence of damage arising from foreign substances (e.g.
oil, or plasticisers in the gas), chemical or electrochemical influences
in the water, or cases when the appliance has come into contact
with unsuitable substances (e.g. chemical products, flammable
substances or unsuitable cleaning agents)
Damage caused by abnormal environmental or unsuitable operat-
ing conditions
Damage caused by force majeure or natural disasters or any other
influences not within Truma’s responsibility
Damage resulting from improper transport
End customer’s or third-party modifications of the appliance, in-
cluding any replacement, supplementary or accessory parts, or
installation of the same, especially concerning the exhaust gas
system or the cowl.

Other manuals for Truma MonoControl CS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma MonoControl CS and is the answer not in the manual?

Truma MonoControl CS Specifications

General IconGeneral
CategoryController
Safety featureCrash sensor
Operating pressure30 mbar
Regulator capacity1.5 kg/h
TypeGas pressure regulator
Gas typePropane/butane
Inlet pressure0.3 to 16 bar
InstallationVertical
Power SupplyNot applicable
DisplayNo