When changing the hose, ensure that the seal provided with
the hose (hose outlet – gas filter / regulator inlet) is correctly
installed and not damaged.
We recommend that the flat gasket G 13 (part no. 50020-76300)
be replaced every time the hose is changed.
Screw the country-specific high-pressure hose (4) to the gas filter(5)/
MonoControl CS inlet and to the cylinder (2 / or the clip-on adapter).
Open the cylinder valve(1).
Press the hose rupture protection (figure1a–3) and if necessary
the yellow reset button (7), turn it slightly clockwise and hold it for
5seconds.
After any intervention, check the hose connection on the cylinder
valve and at the gas filter / MonoControlCS inlet for leaks (see
“Checking for leaks in the high-pressure section”).
Checking for leaks in the high-pressure section
The screw joint of the high-pressure hose at the gas cylinder valve
and on the gas filter / MonoControl CS must be checked for leaks
using suitable means such as a leak-finder spray in accordance with
EN 14291. The operator is responsible for this.
Checking for leaks in the low-pressure section
(maximum test pressure 150 mbar)