17236733/B-10011-5
OPERATION MANUAL
LSC
Submersible Residue Dewatering Pump
LSP
Self-Priming Residue Dewatering Pump
TSURUMI MANUFACTURING CO., LTD.

Other manuals for Tsurumi Pump LSC Series

Questions and Answers

  • S
    Stephanie KingAug 14, 2025
    Why does my Tsurumi Pump Water Pump stop automatically?
    • C
      Carlos RogersAug 14, 2025
      Your Tsurumi Pump Water Pump may be stopping automatically because: * The pump casing is filled with mud. * The voltage is too low. * The pump was operated dry for too long because the suction strainer of the bottom plate is clogged, or it's pumping too much mud. * A 50Hz pump is being operated at 60Hz. To resolve this: 1. Disassemble and clean the pump, detach the suction cover, remove the mud, and manually turn the pump. 2. Raise the voltage to the rated voltage. 3. Remove debris. 4. Check the nameplate and replace the pump or the impeller.
  • W
    washingtonalexAug 17, 2025
    What to do if my Tsurumi Pump LSC is not drawing water?
    • C
      Cristina AndersonAug 17, 2025
      If your Tsurumi Pump Water Pump isn't drawing water, it could be due to the following reasons: * There is no priming water or not enough of it. * The bottom plate is installed incorrectly. * The suction hose or the sweeper suction attachment isn't securely connected. To fix this: 1. Pour fresh water (approximately 1.8L) to prime the pump. 2. Re-install the bottom plate with its arrow facing the suction inlet. 3. Ensure the suction hose or sweeper suction attachment is securely connected.
  • J
    James CisnerosAug 21, 2025
    Why is the pumping head and volume small in my Tsurumi Pump Water Pump?
    • J
      jgriffinAug 21, 2025
      If the pumping head and volume are small in your Tsurumi Pump Water Pump, it could be due to: * The impeller or suction cover being significantly worn. * The drain hose being kinked or clogged. * The suction strainer of the bottom plate being clogged. * The suction inlet being clogged with debris. * A 50Hz pump being operated at 60Hz. To solve this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Remove debris. 4. Remove the bottom plate to remove the debris from the inside of the suction inlet. 5. Check the nameplate and replace the pump or the impeller.
  • D
    David MoodyAug 25, 2025
    How to fix Tsurumi Pump LSC Water Pump that fails to start or stops immediately?
    • M
      malvaradoAug 25, 2025
      If your Tsurumi Pump Water Pump fails to start, or starts but stops immediately, it could be because: * No proper power is supplied (power outage, etc.). * The pump is jammed with debris, causing the motor protector to trip. To resolve this: 1. Contact the electric power company or an electrical repair shop to take action. 2. Inspect the pump unit and remove the debris.
  • A
    Austin SimmonsAug 27, 2025
    Why is the pumping head and volume small and suction performance poor in my Tsurumi Pump LSC?
    • C
      Crystal VegaAug 27, 2025
      If your Tsurumi Pump Water Pump has a small pumping head and volume with poor suction performance, the causes might be: * The impeller or the suction cover is significantly worn. * The drain hose is kinked or clogged. * The suction hose or the sweeper suction attachment is clogged or submerged in sand. * The suction inlet is clogged with debris. * A 50Hz pump is operated at 60Hz. To fix this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Clean the suction hose and the suction attachment. 4. Remove the suction inlet to clean the suction inlet and the check valve. 5. Check the nameplate and replace the pump or the impeller.
  • D
    Diana FischerAug 31, 2025
    What to do if my Tsurumi Pump LSC stops after operating for a while?
    • P
      Patrick JohnsonAug 31, 2025
      If your Tsurumi Pump Water Pump stops after running for some time, it could be due to: * The voltage being too low. * A 50Hz pump being operated at 60Hz. To address this: 1. Raise the voltage to the rated voltage. 2. Check the nameplate and replace the pump or the impeller.
  • K
    Karen AtkinsonSep 3, 2025
    What to do if Tsurumi Pump Water Pump does not draw water at low water level?
    • K
      Kevin HamiltonSep 3, 2025
      If your Tsurumi Pump Water Pump doesn't draw water at a low water level, it's likely because there is no water in the pump. To fix this, prime the pump.
  • E
    Edward CollinsSep 6, 2025
    Why does the priming water flow out after my Tsurumi Pump LSC Water Pump stops?
    • M
      Matthew AndersonSep 7, 2025
      If the priming water flows out after your Tsurumi Pump Water Pump stops, it's likely because the swing check valve and/or the lip on the bottom plate is worn. You should replace the swing check valve and/or the bottom plate.
  • R
    rebecca59Sep 10, 2025
    Why does my Tsurumi Pump Water Pump vibrate or make abnormal sounds?
    • D
      Diane ClarkSep 10, 2025
      If your Tsurumi Pump Water Pump is vibrating or making unusual noises, it's probably because the motor bearings are damaged. You should replace the bearings.

Summary

Operation Manual

Introduction

Safety Precautions

Product Specification Precautions

Precautions related to product specifications for safe operation and to prevent damage.

Transport and Installation Precautions

Safety measures to follow during the transport and installation of the pump.

Test Operation and Operation Precautions

Safety guidelines for conducting test operations and general pump operation.

Maintenance and Inspection Precautions

Safety measures for performing maintenance and inspection tasks on the pump.

Power Outage and Other Precautions

Safety advice for power outages and general usage considerations.

Part Names

Prior to Operation

Product Inspection and Specification Check

Verifying the product's condition, model number, voltage, and frequency.

Accessory and Product Specifications

Confirming included accessories and reviewing major standard specifications.

Installation

Maximum Allowable Water Pressure

Specification for the maximum water pressure the pump can handle during operation.

Preparation for Installation

Tools and instruments required, and site preparation before installing the pump.

Checks to Make Before Installation

Essential checks, like insulation resistance, to perform before commencing installation.

Installation Precautions

Detailed safety measures and operational considerations during pump installation.

Electrical Wiring

Performing Electrical Wiring and Grounding

Procedures for safe electrical wiring, including grounding and regulations.

Connecting the Power Supply

Steps for connecting the power supply, ensuring safety and proper connections.

Cabtyre Cable and Circuit Diagrams

Guidelines for cabtyre cable handling and understanding electrical circuit diagrams.

Motor Protection System

Explanation of the built-in motor protector function and its operation.

Operation

Pre-Operation Checks and Test Run

Verifying settings, conducting a test run, and initial operational steps.

Operating Guidelines and Safety

Key instructions and warnings for safe and effective pump operation.

Maintenance and Inspection

Pre-Inspection and Regular Checks

Steps before inspection and routine checks for weekly and monthly maintenance.

Scheduled Maintenance Tasks

Tasks like oil changes, seal replacement, and general overhaul based on hours or time.

Disassembly and Reassembly Procedure

Disassembly Procedure

Step-by-step guide for disassembling the pump components.

Reassembly Procedure

Steps for correctly reassembling the pump after maintenance or repair.

LSP Specific Disassembly and Reassembly

Specific disassembly and reassembly steps tailored for the LSP model.

Troubleshooting

Tsurumi Pump LSC Series Specifications

General IconGeneral
BrandTsurumi Pump
ModelLSC Series
CategoryWater Pump
LanguageEnglish

Related product manuals