  • S
    Sarah LucasAug 20, 2025
    Why does my Tsurumi Pump LSC1.4S stop automatically?
    • P
      pcarterAug 20, 2025
      Your Tsurumi Pump Water Pump may be stopping automatically because: * The pump casing is filled with mud. * The voltage is too low. * The pump was operated dry for too long because the suction strainer of the bottom plate is clogged, or it's pumping too much mud. * A 50Hz pump is being operated at 60Hz. To resolve this: 1. Disassemble and clean the pump, detach the suction cover, remove the mud, and manually turn the pump. 2. Raise the voltage to the rated voltage. 3. Remove debris. 4. Check the nameplate and replace the pump or the impeller.
  • G
    Gary CarrollAug 22, 2025
    What to do if my Tsurumi Pump LSC1.4S Water Pump is not drawing water?
    • E
      Emily AndersonAug 22, 2025
      If your Tsurumi Pump Water Pump isn't drawing water, it could be due to the following reasons: * There is no priming water or not enough of it. * The bottom plate is installed incorrectly. * The suction hose or the sweeper suction attachment isn't securely connected. To fix this: 1. Pour fresh water (approximately 1.8L) to prime the pump. 2. Re-install the bottom plate with its arrow facing the suction inlet. 3. Ensure the suction hose or sweeper suction attachment is securely connected.
  • J
    Janet PatelAug 25, 2025
    Why is the pumping head and volume small in my Tsurumi Pump LSC1.4S Water Pump?
    • L
      Leah VaughnAug 25, 2025
      If the pumping head and volume are small in your Tsurumi Pump Water Pump, it could be due to: * The impeller or suction cover being significantly worn. * The drain hose being kinked or clogged. * The suction strainer of the bottom plate being clogged. * The suction inlet being clogged with debris. * A 50Hz pump being operated at 60Hz. To solve this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Remove debris. 4. Remove the bottom plate to remove the debris from the inside of the suction inlet. 5. Check the nameplate and replace the pump or the impeller.
  • A
    annjohnsonAug 27, 2025
    How to fix Tsurumi Pump Water Pump that fails to start or stops immediately?
    • S
      Stacie RhodesAug 27, 2025
      If your Tsurumi Pump Water Pump fails to start, or starts but stops immediately, it could be because: * No proper power is supplied (power outage, etc.). * The pump is jammed with debris, causing the motor protector to trip. To resolve this: 1. Contact the electric power company or an electrical repair shop to take action. 2. Inspect the pump unit and remove the debris.
  • A
    Alexis SpearsAug 28, 2025
    Why is the pumping head and volume small and suction performance poor in my Tsurumi Pump Water Pump?
    • K
      Kathryn RossAug 28, 2025
      If your Tsurumi Pump Water Pump has a small pumping head and volume with poor suction performance, the causes might be: * The impeller or the suction cover is significantly worn. * The drain hose is kinked or clogged. * The suction hose or the sweeper suction attachment is clogged or submerged in sand. * The suction inlet is clogged with debris. * A 50Hz pump is operated at 60Hz. To fix this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Clean the suction hose and the suction attachment. 4. Remove the suction inlet to clean the suction inlet and the check valve. 5. Check the nameplate and replace the pump or the impeller.
  • A
    Amy HartAug 30, 2025
    What to do if my Tsurumi Pump Water Pump stops after operating for a while?
    • J
      Joseph RussoAug 30, 2025
      If your Tsurumi Pump Water Pump stops after running for some time, it could be due to: * The voltage being too low. * A 50Hz pump being operated at 60Hz. To address this: 1. Raise the voltage to the rated voltage. 2. Check the nameplate and replace the pump or the impeller.
  • S
    Sandra JonesAug 31, 2025
    What to do if Tsurumi Pump LSC1.4S does not draw water at low water level?
    • L
      Leslie LunaSep 1, 2025
      If your Tsurumi Pump Water Pump doesn't draw water at a low water level, it's likely because there is no water in the pump. To fix this, prime the pump.
  • K
    Kristin WadeSep 2, 2025
    Why does the priming water flow out after my Tsurumi Pump LSC1.4S Water Pump stops?
    • S
      savannah44Sep 2, 2025
      If the priming water flows out after your Tsurumi Pump Water Pump stops, it's likely because the swing check valve and/or the lip on the bottom plate is worn. You should replace the swing check valve and/or the bottom plate.
  • A
    Aaron SweeneySep 4, 2025
    Why does my Tsurumi Pump LSC1.4S vibrate or make abnormal sounds?
    • N
      Nicholas StarkSep 4, 2025
      If your Tsurumi Pump Water Pump is vibrating or making unusual noises, it's probably because the motor bearings are damaged. You should replace the bearings.
  • J
    Jeremy ThompsonSep 6, 2025
    Why does my Tsurumi Pump LSC1.4S Water Pump start but stop?
    • R
      Ronald NicholsSep 6, 2025
      If your Tsurumi Pump Water Pump starts but then stops, several factors could be at play. The motor windings or cable might be damaged, so check them. An impeller could be blocked or choked. Also, wrong voltage or frequency could be the reason. Check the voltage under load if it seems too low. If a generating set provides power, the frequency may be inexact. Excessive viscosity or density of the liquid could also be the reason. Finally, there might be a wrong setting or thermal overload at the power source.

Summary

Safety Precautions

Product Specification Precautions

Safety measures concerning product specifications and usage conditions.

Transport and Installation Safety

Key safety guidelines for handling and installing the pump.

Test Operation and General Operation Safety

Safety measures for testing and operating the pump, including warnings.

Maintenance and Inspection Safety

Critical safety precautions to follow during maintenance and inspection.

Power Outage Safety

Precautions to take regarding power outages and their impact on the pump.

Pump Installation

Installation Precautions

Essential safety guidelines and operational tips during pump installation.

Electrical Wiring

Pump Operation

Safe Operation Procedures

Guidelines and warnings for safe and continuous pump operation.

Maintenance and Inspection

Disassembly and Reassembly Procedures

Troubleshooting Guide

Tsurumi Pump LSC1.4S Specifications

General IconGeneral
BrandTsurumi Pump
ModelLSC1.4S
CategoryWater Pump
LanguageEnglish

Related product manuals