17236733/B-10011-5
OPERATION MANUAL
LSC
Submersible Residue Dewatering Pump
LSP
Self-Priming Residue Dewatering Pump
TSURUMI MANUFACTURING CO., LTD.

Questions and Answers

  • J
    James MoyerAug 14, 2025
    Why does my Tsurumi Pump Water Pump stop automatically?
    • K
      Kelly PaulAug 14, 2025
      Your Tsurumi Pump Water Pump may be stopping automatically because: * The pump casing is filled with mud. * The voltage is too low. * The pump was operated dry for too long because the suction strainer of the bottom plate is clogged, or it's pumping too much mud. * A 50Hz pump is being operated at 60Hz. To resolve this: 1. Disassemble and clean the pump, detach the suction cover, remove the mud, and manually turn the pump. 2. Raise the voltage to the rated voltage. 3. Remove debris. 4. Check the nameplate and replace the pump or the impeller.
  • J
    Justin GonzalezAug 18, 2025
    What to do if my Tsurumi Pump LSP.1.4S is not drawing water?
    • E
      Edward WilliamsAug 18, 2025
      If your Tsurumi Pump Water Pump isn't drawing water, it could be due to the following reasons: * There is no priming water or not enough of it. * The bottom plate is installed incorrectly. * The suction hose or the sweeper suction attachment isn't securely connected. To fix this: 1. Pour fresh water (approximately 1.8L) to prime the pump. 2. Re-install the bottom plate with its arrow facing the suction inlet. 3. Ensure the suction hose or sweeper suction attachment is securely connected.
  • R
    rosephyllisAug 21, 2025
    Why is the pumping head and volume small in my Tsurumi Pump LSP.1.4S Water Pump?
    • A
      aprilwheelerAug 21, 2025
      If the pumping head and volume are small in your Tsurumi Pump Water Pump, it could be due to: * The impeller or suction cover being significantly worn. * The drain hose being kinked or clogged. * The suction strainer of the bottom plate being clogged. * The suction inlet being clogged with debris. * A 50Hz pump being operated at 60Hz. To solve this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Remove debris. 4. Remove the bottom plate to remove the debris from the inside of the suction inlet. 5. Check the nameplate and replace the pump or the impeller.
  • H
    Heather GriffinAug 25, 2025
    How to fix Tsurumi Pump LSP.1.4S that fails to start or stops immediately?
    • D
      dtrujilloAug 25, 2025
      If your Tsurumi Pump Water Pump fails to start, or starts but stops immediately, it could be because: * No proper power is supplied (power outage, etc.). * The pump is jammed with debris, causing the motor protector to trip. To resolve this: 1. Contact the electric power company or an electrical repair shop to take action. 2. Inspect the pump unit and remove the debris.
  • K
    Karen HartAug 27, 2025
    Why is the pumping head and volume small and suction performance poor in my Tsurumi Pump Water Pump?
    • J
      Jeff PerezAug 28, 2025
      If your Tsurumi Pump Water Pump has a small pumping head and volume with poor suction performance, the causes might be: * The impeller or the suction cover is significantly worn. * The drain hose is kinked or clogged. * The suction hose or the sweeper suction attachment is clogged or submerged in sand. * The suction inlet is clogged with debris. * A 50Hz pump is operated at 60Hz. To fix this: 1. Repair or replace the affected part. 2. Straighten the curved or kinked part as much as possible. 3. Clean the suction hose and the suction attachment. 4. Remove the suction inlet to clean the suction inlet and the check valve. 5. Check the nameplate and replace the pump or the impeller.
  • A
    andrew06Aug 31, 2025
    What to do if my Tsurumi Pump LSP.1.4S Water Pump stops after operating for a while?
    • C
      christopher17Aug 31, 2025
      If your Tsurumi Pump Water Pump stops after running for some time, it could be due to: * The voltage being too low. * A 50Hz pump being operated at 60Hz. To address this: 1. Raise the voltage to the rated voltage. 2. Check the nameplate and replace the pump or the impeller.
  • K
    Kimberly ClineSep 3, 2025
    What to do if Tsurumi Pump LSP.1.4S does not draw water at low water level?
    • K
      Kaitlyn PriceSep 3, 2025
      If your Tsurumi Pump Water Pump doesn't draw water at a low water level, it's likely because there is no water in the pump. To fix this, prime the pump.
  • J
    James PerrySep 7, 2025
    Why does the priming water flow out after my Tsurumi Pump Water Pump stops?
    • J
      Jacob SmithSep 7, 2025
      If the priming water flows out after your Tsurumi Pump Water Pump stops, it's likely because the swing check valve and/or the lip on the bottom plate is worn. You should replace the swing check valve and/or the bottom plate.
  • M
    Michael MurraySep 10, 2025
    Why does my Tsurumi Pump LSP.1.4S Water Pump vibrate or make abnormal sounds?
    • R
      Rebecca AnthonySep 10, 2025
      If your Tsurumi Pump Water Pump is vibrating or making unusual noises, it's probably because the motor bearings are damaged. You should replace the bearings.

Summary

1 BE SURE TO READ FOR YOUR SAFETY

PRECAUTIONS TO THE PRODUCT SPECIFICATIONS

Safety warnings regarding operating conditions and specifications.

PRECAUTIONS DURING TRANSPORT AND INSTALLTION

Safety warnings for handling and installing the pump to prevent damage or injury.

PRECAUTIONS DURING TEST OPERATION AND OPERATION

PRECAUTIONS DURING MAINTENANCE AND INSPECTION

3 PRIOR TO OPERATION

4 INSTALLATION

Precautions in Installation

5 ELECTRICAL WIRING

Grounding

Importance of proper grounding to prevent electrical shock.

Connecting the power supply

Procedures and warnings for connecting the power supply safely.

Cabtyre cable

Motor Protection system

6 OPERATION

Test Operation

Procedures for performing a short test run of the pump.

Operation

General guidance and warnings for operating the pump.

7 MAINTENANCE AND INSPECTION

Oil Inspection and Oil change

8 DISASSEMBLY AND REASSEMBLY PROCEDURE

Disassembly(LSP)

Reassembly

9 TROUBLESHOOTING

Tsurumi Pump LSP.1.4S Specifications

General IconGeneral
ModelLSP.1.4S
TypeSubmersible Pump
Power1.4 kW
Motor Output1.4 kW
Motor PhaseSingle Phase

Related product manuals