7. OPERATION OF THE SYSTEM
ThecongurationoftheMCsystempermitsrequiringtheUsertoenterfurtheroptionaldata
(vehiclelicenceplate,mileage,quantitytobedispensed).
Fordetails,seetheMCcontrolsystemmanual.
Intheeventthattheseoptionsarenotset,MCwillrecogniseanactivatedPINCODEand,once
thenozzlecontact(ifapplicable)hasbeenclosed,thepumpisenabled,allowingittodispense.
Thepumpwillstart(ifpreviouslyenabled)justassoonasthecontrolleverismovedtoON
position,whileitswitcheso󰀨assoonasthecontrolleverismovedtoOFFposition.
Nofurthermanualoperationisrequiredtostartorstopthepump.
Fuel dispensing
Inthecaseofthesimplestconguration(nooptionaldatarequired),thefueldispensing
procedureisthefollowing:
• Insert PIN CODE
(orapplytheelectronickey)
IftheMCrecognisestheactivatedPIN
(orkey),a“GOODMORNINGMANAGER/
USER”messageisdisplayedandthe
pumpenabled.
WARNING
Such enabling does not result in immediate pump startup. The pump is in fact
controlled by a switch (positioned in the nozzle seat) operated by the user.
WARNING
Fuel must ONLY be dispensed under the careful control of the user.
7. OPERATION OF THE SYSTEM
4. Watchman Sonic
1. CHECK LEVEL, DISTANCE AND HEIGHT
EnsurebeforeyoustartyourinstallthatthetanktheWatchmanSonicistobettedtois:
1.Onaatlevelbase.
2.Withina200metrerangefromreceiverposition.
3.Amaximumactualtankheightof3metres.50metree󰀨ectiverange(200metreclearlineof
sight).
4.Tankmustbettedinaccordancewithmanufacturersguidelines&instructions.
NB:Anyradiofrequencysignalmaybeseriouslyinhibitedifpositionedunderground.Pleasecheck
thatthetransmitter/receiverlinkworksinthedesiredlocationbeforeinstallation.
2. TANK PREPARATION
Pleasenote-itisimportanttokeepallitemsdryduringinstallation.
A)PRE-DRILLEDTANKS.
Theremayalreadybea32mmpre-drilledopeninginthe
tanktopandpossiblyatubetted.Ifso,removethecover
byundoingthetwoscrewsholdingitinplace,anddispose
ofthetubeinaccordancewithlocalgovernmentguidelines.
NB–EnsuretheholeisaminimumDIAMETER30mm.
EnsurethatthespacebeneaththeWatchmanSonicunitis
freeofanyobstaclesandthattheltrasonicbeampathis
clearofobstructions.(SeePicture2)
B)UN-DRILLEDTANKS.
Wheredrillingisrequiredtotthetransmitter,
chooseaatlevelpointthatisatthesamelevel
andnolowerthananyopeningatthetopofthe
tank(llingpointetc.).
(SeePicture3)