NGC Energy.xls
NGC Tornado (1 PHASE)
Changeable Parameters
Operating Time 12 Hours
Energy Costs $0.11 kWHr
Snooze Mode 0.00 Hours
Cook Cycles/Day 100 Cooks/Day
Typical Cook Time 60 Seconds
Do Not Change the following values
Time (min)
Power
(Watts) Cost/Day Balance of Time (hrs)
Warm up
15 5277 $0.15 11.75
Cooking
100
5000
$0.96
10.08
Snooze Idle
0
1100
$0.00
10.08
Idle
605
1400
$1.62
0
Total/Day
$2.72 Yearly
Total/Month
$81.72
$980.62
HVAC Requirements Per Operating Time -- Note: Approximations Only
Average Energy Cooking And Idle (J) Warmup Energy (J)
Total
Energy (J)
Total average
Power (W)
Total Environmental
Load kBtu/hr
Average
Cooling
Requirement
(ton of AC)
80820000
4749300
85569300
1981
6.759028
0.563