Rebar Scanner A60+
19
COM port transfer interface is shown as figure 3-15. Press the
ENTER key to carry out transfer and press the ESC key to return
function selection interface without transferring data. After transfer is
end, prompt Transfer End, as figure 3-16 shows. Then press any key to
return function selection interface.
Connect by COM
[ESC] : cancel
[ENTER] : confirm
Figure 3-15 COM port transfers
Figure 3-16 Transfer end
3.2.7 View data
Interface of viewing data is showed as figure 3-17, figure 3-18,
figure 3-19 and figure 3-20. Project No. region is on the left side.
Selected project data region is on the right side. Project whose No. is
begun with 1XXX includes data of detecting covering layer thickness
under the condition of known rebar diameter. Project whose No. is
begun with 2XXX includes data of detecting rebar diameter and
covering layer thickness at the same time under the condition of
unknown rebar diameter. Project whose No. is begun with 3XXX
T
Press any key to return!