Notes:
l PIR beams can extend past the set range coverage distance if you direct the detector at an open space.
l To calibrate the detector sensitivity to identify persons more accurately, set the detector detection range. For more information, see Configuring the
detector parameters .
l To protect a window, mount the detector on an upper corner of the window frame so that the PIR beams are parallel with the glass pane.
3. Mounting the MP-902 PG2
To mount the MP-902 PG2, complete the following steps:
1. Use the uppermost and middle holes in the device bracket to mark two holes in the mounting surface. See Hole Number 1 and Hole Number 2 in
Figure 4.
2. Optional:To avail of tamper protection, use the bottommost hole in the break-away segment of the bracket to mark a third hole in the mounting
surface. See Hole Number 3 in Figure 4.
3. Drill the required holes in the mounting surface according to the markings and insert the wall plugs. See Figure 5.
4. Fasten the bracket to the mounting surface with screws. See Figure 6.
5. Insert the batteries into the detector and close the battery cover. For more information, see Inserting or replacing the batteries.
6. Insert the top of the detector into the bracket. As you insert the detector, choose a slot in the bracket that positions the detector to cover the area
that requires protection. See Figure 7 and Figure 8.
Note:When you complete Step 6, a blinking LED indicates the start of the tamper self-calibrating procedure.
Note: When the detector is resting on the unscrewed bracket, it can be rotated freely to a more exact final position. See Hole Number 1 in Figure
9.
7. While the LED is blinking, tighten the bottom screw to close the bracket. See number 2 in Figure 9.
Note: If the yellow LED stops blinking before the screw is tightened adequately, remove the detector from the bracket and wait three seconds.
Repeat Step 6 to start the self-calibrating procedure.
Figure 4:
Marking the screw holes
Figure 5:
Drilling the screw holes
Figure 6:
Fastening the bracket
Figure 7:
Rotation slot
Figure 8: Slotting into the device
Figure 9:
Closing the bracket
D-307164 MP-902 PG2 Installation instructions 2