D-307164 MP-902 PG2 Installation instructions 1
1. Overview
The MP-902 PG2 is a smart, wireless outdoor curtain PIR detector with
anti-masking. It is supported by the PowerMaster alarm system and uses
PowerG two-way communication protocol.
The detector has the following features:
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Two channel Pyro (patented) thermal sensor output
Microprocessor-controlled temperature compensation
White light protection
Adjustable pet immunity selector with three options: no pet, a small pet
weighing less than 3 kg or 6.6 lb, or a pet weighing less than 18 kg
or 40 lb.
Adjustable detection sensitivity
Parabolic and elliptical optics (patented)
Target Specific Imaging™ (TSI) technology distinguishes between
humans and pets weighing up to 18 kg or 40 lbs
True Motion Recognition™ algorithm (patented) distinguishes
between the true motion of an intruder and any other disturbances
which may cause false alarms.
Cross-direction detection: both directions, left to right, and right to left.
Active smart anti-masking ability recognizes spray and dust (patented)
No vertical adjustment is needed.
Long-life battery which is due to the ultralow current consumption
Front and back tamper protection (patented)
Supports temperature and light level reports according to the PowerG
panel version
Note:For UL installations, only use the device with UL listed control units.
Figure 1: MP-902 PG2
1. Bracket
2. Detector
3. Indication LED
4. PIR optical window
2. Installation advice
Qualified service persons only can install the MP-902 PG2. Before you install the device, consider the following points:
l Install the MP-902 PG2 according to the Standard for Installation and
Classification of Burglar and Holdup Alarm Systems, UL 681.
l Mount the detector so that the expected movement of the intruder will
cross the PIR beam.
l Mount the device on a vertical surface and as straight as possible.
l Mount the device upright. See Figure 2.
l Direct the detector at a stable surface, such as a wall or fence, to
provide a curtain detection boundary for better detection.
l Mount the device at a height that agrees with your pet immunity
preference. See Setting the pet immunity for more information.
l Consider weather conditions that can trigger false alarms, such as
moving tree branches or leaves, and other related environmental
conditions
l Locate the device at least 20 cm from all persons during normal
operation to comply with FCC and ISED Canada RF exposure
compliance requirements
l Install the device over sloped ground. See Figure 3.
l Install the device close to tree branches as weather conditions can
cause movement, resulting in false alarms
l Install the device in hazardous locations
l Install the device in areas with a pollution degree higher than pollution
degree 2
l Install the device in circuits above overvoltages category II
l Obscure the field of view of the detector
l Co-locate or operate the antennas used for this product in conjunction
with any other antenna or transmitter
l Mount the device on surfaces where surface vibration can occur
Figure 2:
Mounting orientation
Figure 3: Flat ground installation
MP-902 PG2
Wireless outdoor curtain PIR detector with anti-masking and pet immunity
Installation instructions
Do:
Do
not:
Question and Answer IconNeed help?

Do you have a question about the Tyco MP-902 PG2 and is the answer not in the manual?

Tyco MP-902 PG2 Specifications

General IconGeneral
ManufacturerTyco
Field of View/Coverage Angle90 degrees
Operating Temperature-10°C to 55°C (14°F to 131°F)
Tamper ProtectionYes
CompatibilityPowerMaster Systems
Product TypeMotion Detector
TechnologyPassive Infrared (PIR)
Frequency433MHz
Pet ImmunityUp to 38 kg (85 lbs)
Detection Range12 meters (39 feet)
Battery Type3V Lithium Battery
Mounting Height2.3 to 2.4 meters

Summary

1. Overview

2. Installation advice

3. Mounting the MP-902 PG2

4. Enrolling the MP-902 PG2

5. Configuring the detector parameters

5.1. Modifying the MP-902 PG2

Adjust detector settings like alarm LED, PIR range, and outdoor anti-masking.

5.2. Configuring the temperature alerts

Set alerts for temperature thresholds (very hot, cold, freezing) and their delay times.

5.3. Setting the detector range

Configure detection range sensitivity based on panel version and desired coverage.

6. Inserting or replacing the batteries

7. Setting the pet immunity

8. Performing a walk test

9. LED operation

10. Temperature Display

11. Compatible receivers

12. Specifications

13. Compliance with standards

Related product manuals