Table of Contents

Questions and Answers

  • D
    Donna OrrAug 18, 2025
    Why is the Tylo Iron steam room taking so long to heat up?
    • J
      Joseph WeberAug 19, 2025
      If your Tylo Iron steam room is heating up slowly, consider these potential causes. A low power steam generator may be insufficient, suggesting a change to a higher power model. Excessive ventilation can hinder heating, so reduce it. Check for blown or tripped fuses in the distribution board and replace them. If the surrounding air temperature is below 15°C, raise it or switch to a more powerful steam generator. A broken pipe element will also slow heating and needs replacement. Lastly, ensure the sensor isn't too close to the steam; if it is, move it or adjust the steam jet's direction.
  • B
    Bridget GrayAug 21, 2025
    What to do if hot water runs out through the Tylo Iron steam nozzle with little steam?
    • N
      Nancy HarperAug 22, 2025
      If hot water is running out of the Tylo Iron steam nozzle with little to no steam, the feed water solenoid valve may be jammed. Try removing and cleaning the solenoid valve, or address any electrical faults. If the solenoid valve is broken, replace it. Alternatively, there could be a circuit board fault, requiring replacement of the circuit board. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits are removed.
  • D
    dixonshariAug 25, 2025
    Why is the desired temperature maintained in the Tylo Commercial 12 kW Iron steam room, but there is no steam?
    • V
      Veronica GreenAug 25, 2025
      If your Tylo Iron steam room maintains the desired temperature but produces no steam, it could be due to several reasons. Insufficient ventilation may be the cause, so increase the amount of ventilation. If the incoming air temperature is too high, reduce it to a maximum of 35°C. Also, ensure that the surrounding temperature does not exceed 35°C. Finally, check the thermometer's location; it should be approximately 150-170 cm above the floor and away from the steam jet. If the thermometer is faulty, replace it.
  • R
    Ryan YoungAug 27, 2025
    What causes loud banging in the water lines of a Tylo Commercial 12 kW when the solenoid valve opens or closes?
    • K
      Kristen ClayAug 27, 2025
      Loud banging in the water lines of your Tylo Iron when the solenoid valve operates can be caused by a couple of issues. First, ensure the incoming water piping to the steam generator is securely fastened to the wall using clamps. If the banging persists, it could be due to recoil (water hammer) in the incoming water piping. To resolve this, replace about 1 meter of the water piping nearest the steam generator with a flexible type, such as an armored rubber hose capable of withstanding the water pressure.
  • C
    Courtney FloresAug 30, 2025
    What causes steam production to come and go at short intervals in my Tylo Commercial 12 kW?
    • N
      Nicole MaysAug 30, 2025
      Inconsistent steam production in your Tylo Iron could be due to a couple of factors. Check the sensor's positioning relative to the steam; if it's not correct, move the sensor or change the direction of the steam jet. Also, inspect the dirt filter for limescale or foreign material, and remove and clean the dirt filter if necessary.
  • B
    Brittany GarrisonSep 3, 2025
    Why does hot water squirt jerkily out through the steam nozzle of my Tylo Commercial 12 kW?
    • J
      Jesse MartinSep 3, 2025
      If hot water squirts jerkily or trickles out of the Tylo Iron steam nozzle mixed with steam, it could be due to a small water pocket in the steam pipe; eliminate the water pocket. Alternatively, an excessive length of uninsulated steam pipe could be the cause, so insulate the steam pipe. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits have been removed.
  • S
    Shaun StoneSep 5, 2025
    What causes the safety valve to open or temperature protection to trip on a Tylo Commercial 12 kW Iron?
    • A
      Anna MillerSep 6, 2025
      If the safety valve opens or the temperature protection trips on your Tylo Iron, it could be due to a few reasons. If the internal diameter of the steam piping is significantly reduced, change the pipe or joint component causing the reduction, ensuring a minimum internal diameter of 12 mm. If there are several sharp bends in the steam pipe, replace them with gently rounded bends (minimum radius 50 mm). Excessive limescale in the steam generator water can also cause this issue; descale several times, flushing in between. If that doesn't work, change the water tank, complete with the element and electrodes.
  • E
    ericandrewsSep 9, 2025
    What to do if hot water runs continuously out from the Tylo Commercial 12 kW Iron steam generator drain pipe?
    • J
      jameshensleySep 9, 2025
      If hot water continuously runs out from the Tylo Iron steam generator drain pipe, the automatic draining solenoid valve may be jammed. Switch off the steam generator and test again after 80 minutes. If the fault persists, remove the motorized ball valve for the automatic drain function and clean it.
  • F
    fmyersSep 12, 2025
    What to do if fan or lighting not working in Tylo Commercial 12 kW Iron despite correct connections?
    • M
      Michael CampbellSep 12, 2025
      If the fan or lighting in your Tylo Iron isn't working despite correct connections, a fuse may have blown or tripped. Replace the fuse.
  • V
    Vanessa MartinezNov 14, 2025
    What to do if neither steam nor heat are present in the Tylo Iron steam room?
    • E
      Edward KellyNov 15, 2025
      If there's no steam or heat in your Tylo Iron steam room, several issues could be the cause. First, check if the fuses in the distribution board have blown or tripped and replace them if necessary. Ensure water is entering the steam generator by opening the connected tap and inspecting the hose for kinks. Verify the control panel's time and temperature settings are correct. Also, inspect and clean the dirt filter connected to the incoming water line. Remove and clean the feed water solenoid valve to clear any blockages. If there's excessive limescale, replace the water tank, element, and electrodes. Confirm the steam generator is connected to the correct voltage, referring to the wiring diagram. Finally, a fault in the circuit board, control panel, or solenoid valve may require replacing t...

Summary

Pipework Installation

Water connection instructions

Provides instructions for connecting the cold water supply to the generator.

Steam pipe installation

Guides on fitting and routing the steam pipe, including bend radius.

Drainage connection

Details the connection and slope requirements for the drain pipe and safety valve.

Electrical Installation

Trouble shooting

No steam inside the room

Addresses symptoms, causes, and remedies when no steam is produced despite temperature.

Slow warm-up time

Details common causes and solutions for the steam room taking too long to heat up.

No steam or heat

Covers troubleshooting steps when neither steam nor heat is generated by the system.

Loud banging in water lines

Explains causes and remedies for banging sounds in the water supply pipes.

Safety valve or temp. cut-out trips

Addresses issues that cause the safety valve or temperature protection to activate.

Intermittent steam production

Describes problems where steam production is inconsistent or stops and starts.

Error codes

Descaling procedures