Questions and Answers

  • J
    Joseph RayAug 18, 2025
    Why is the Tylo Iron steam room taking so long to heat up?
    • K
      Katherine RodriguezAug 18, 2025
      If your Tylo Iron steam room is heating up slowly, consider these potential causes. A low power steam generator may be insufficient, suggesting a change to a higher power model. Excessive ventilation can hinder heating, so reduce it. Check for blown or tripped fuses in the distribution board and replace them. If the surrounding air temperature is below 15°C, raise it or switch to a more powerful steam generator. A broken pipe element will also slow heating and needs replacement. Lastly, ensure the sensor isn't too close to the steam; if it is, move it or adjust the steam jet's direction.
  • T
    Tracy PooleAug 21, 2025
    What to do if hot water runs out through the Tylo Home 3/6/9 kW steam nozzle with little steam?
    • E
      Emily MeyerAug 21, 2025
      If hot water is running out of the Tylo Iron steam nozzle with little to no steam, the feed water solenoid valve may be jammed. Try removing and cleaning the solenoid valve, or address any electrical faults. If the solenoid valve is broken, replace it. Alternatively, there could be a circuit board fault, requiring replacement of the circuit board. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits are removed.
  • R
    rodneycastroAug 25, 2025
    Why is the desired temperature maintained in the Tylo Iron steam room, but there is no steam?
    • A
      Alexandra BrooksAug 25, 2025
      If your Tylo Iron steam room maintains the desired temperature but produces no steam, it could be due to several reasons. Insufficient ventilation may be the cause, so increase the amount of ventilation. If the incoming air temperature is too high, reduce it to a maximum of 35°C. Also, ensure that the surrounding temperature does not exceed 35°C. Finally, check the thermometer's location; it should be approximately 150-170 cm above the floor and away from the steam jet. If the thermometer is faulty, replace it.
  • N
    nicholsjeffreyAug 27, 2025
    What causes loud banging in the water lines of a Tylo Iron when the solenoid valve opens or closes?
    • J
      Jeffrey NguyenAug 27, 2025
      Loud banging in the water lines of your Tylo Iron when the solenoid valve operates can be caused by a couple of issues. First, ensure the incoming water piping to the steam generator is securely fastened to the wall using clamps. If the banging persists, it could be due to recoil (water hammer) in the incoming water piping. To resolve this, replace about 1 meter of the water piping nearest the steam generator with a flexible type, such as an armored rubber hose capable of withstanding the water pressure.
  • A
    Aaron ReedAug 30, 2025
    What causes steam production to come and go at short intervals in my Tylo Home 3/6/9 kW Iron?
    • C
      Catherine SantiagoAug 31, 2025
      Inconsistent steam production in your Tylo Iron could be due to a couple of factors. Check the sensor's positioning relative to the steam; if it's not correct, move the sensor or change the direction of the steam jet. Also, inspect the dirt filter for limescale or foreign material, and remove and clean the dirt filter if necessary.
  • B
    becky85Sep 2, 2025
    Why does hot water squirt jerkily out through the steam nozzle of my Tylo Home 3/6/9 kW?
    • P
      phillipshollySep 3, 2025
      If hot water squirts jerkily or trickles out of the Tylo Iron steam nozzle mixed with steam, it could be due to a small water pocket in the steam pipe; eliminate the water pocket. Alternatively, an excessive length of uninsulated steam pipe could be the cause, so insulate the steam pipe. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits have been removed.
  • N
    Natalie BensonSep 5, 2025
    What causes the safety valve to open or temperature protection to trip on a Tylo Home 3/6/9 kW?
    • M
      michaeljohnsonSep 5, 2025
      If the safety valve opens or the temperature protection trips on your Tylo Iron, it could be due to a few reasons. If the internal diameter of the steam piping is significantly reduced, change the pipe or joint component causing the reduction, ensuring a minimum internal diameter of 12 mm. If there are several sharp bends in the steam pipe, replace them with gently rounded bends (minimum radius 50 mm). Excessive limescale in the steam generator water can also cause this issue; descale several times, flushing in between. If that doesn't work, change the water tank, complete with the element and electrodes.
  • K
    Kristina DavenportSep 8, 2025
    What to do if hot water runs continuously out from the Tylo Iron steam generator drain pipe?
    • S
      Sandra RaySep 8, 2025
      If hot water continuously runs out from the Tylo Iron steam generator drain pipe, the automatic draining solenoid valve may be jammed. Switch off the steam generator and test again after 80 minutes. If the fault persists, remove the motorized ball valve for the automatic drain function and clean it.
  • S
    Sara RodriguezSep 12, 2025
    What to do if fan or lighting not working in Tylo Iron despite correct connections?
    • J
      Jeremy MoralesSep 12, 2025
      If the fan or lighting in your Tylo Iron isn't working despite correct connections, a fuse may have blown or tripped. Replace the fuse.
  • M
    Michael ColeNov 14, 2025
    What to do if neither steam nor heat are present in the Tylo Iron steam room?
    • P
      Paul MunozNov 15, 2025
      If there's no steam or heat in your Tylo Iron steam room, several issues could be the cause. First, check if the fuses in the distribution board have blown or tripped and replace them if necessary. Ensure water is entering the steam generator by opening the connected tap and inspecting the hose for kinks. Verify the control panel's time and temperature settings are correct. Also, inspect and clean the dirt filter connected to the incoming water line. Remove and clean the feed water solenoid valve to clear any blockages. If there's excessive limescale, replace the water tank, element, and electrodes. Confirm the steam generator is connected to the correct voltage, referring to the wiring diagram. Finally, a fault in the circuit board, control panel, or solenoid valve may require replacing t...

Summary

General Installation Guidelines

Steam Generator Location

Guidance on where to install the steam generator, including distance limits.

Pipework Installation

Water Connection

Instructions for connecting the cold water supply to the steam generator.

Steam Pipe Installation

Guidelines for installing the steam pipe, including material and slope.

Drainage System

Instructions for connecting the drain pipe from the steam generator.

Electrical Installation

Electrical Connections Diagram

Visual guide for wiring the steam generator and control systems.

Troubleshooting Guide

No Steam in Room

Diagnosing and resolving issues when no steam is produced despite heating.

No Steam or Heat

Troubleshooting absence of both steam and heat in the room.

Hot Water from Nozzle

Addressing problems where hot water, not steam, is emitted from the nozzle.

Jerky Steam;Hot Water Mix

Resolving inconsistent steam output or mixed hot water flow.

Continuous Drain Flow

Troubleshooting a constant flow from the steam generator's drain pipe.

Error Code Diagnostics

Error Code 1: Temperature Sensor Fault

Symptoms, causes, and remedies for temperature sensor connection or fault issues.

Error Code 2: Temperature Sensor Fault

Detailed information on temperature sensor issues affecting system standby.

Error Code 4: Level Electrodes Short-Circuited

Identifying and fixing short-circuits in the steam tank level electrodes.

Error Code 5: Steam Tank Level Electrodes Not Working

Troubleshooting issues with the steam tank's mid and high level electrodes.

Error Code 12: Steam Tank Level Electrodes (Mid Failure)

Specific issues with steam tank level electrodes indicating mid failure.

Descaling Procedure

Tylo Home 3/6/9 kW Specifications

General IconGeneral
BrandTylo
ModelHome 3/6/9 kW
CategoryIron