22
IMPORTANT! There must not be any kind of blockage in
the steam piping (taps, etc.). The internal diameter of the steam
piping must not be reduced.
If the steam pipe is longer than 3 meters, it should be heat in-
sulated with an insulation that can tolerate at least 100°C. If the
pipe is not insulated, there is a risk that the steam will cool and
condense, resulting in water in the steam pipe.
The distance between infl ammable material, such as wood, and
an uninsulated steam pipe must not be less than 10 mm.
When running piping through walls, the hole for the lead-through
must have a diameter that is 10 mm greater that the external
diameter of the pipe.
IMPORTANT!
The steam nozzle is installed inside the steam room at least 40
cm above fl oor level. Do not locate the nozzle so that the steam
jet will hit the wall, seating area or any other object, there must be
at least 80 cm clear area in front of the steam nozzle. If the steam
room is to be used by children or anyone with a reduced reaction
ability or similar, there must be protection present that will prevent
unintentional contact with the steam jet nearest to the steam
nozzle.
If the steam nozzle will be installed in a Tylö steam room, refer
to the installation instructions that accompany the steam room.
IMPORTANT! There must not be any kind of blockage on
the steam head (e.g. taps or valves).
Fitting the steam head, please see the instructions supplied with
Bahia Home or Bahia PRO.
Fig. 9
Fig. 10
Drainage
For drainage connect a copper pipe of good quality and an
internal diameter of at least 25 mm to connection 3 (Fig. 6,7) on
the steam generator. The steam generator drain pipe is led to the
nearest drain outside the steam room. The temperature of the
water being drained is about 80-85°C.
To reduce the temperature of the water and reduce the risk of
scale build-up in the drain, a washbasin can be installed between
the steam generator and the drain. (Tylö Item no. 9002 9060)
IMPORTANT!
There must not be any kind of blockage in the drain piping (e.g.
taps or valves). The drain pipe must have a continuous down-slo-
pe all the way from the steam generator to the drain.
A draining pipe connected to the safety valve D (0)(Fig. 6 and 7)
is to be installed in a continuously downward direction and in a
frost-free environment.
The steam pipe should have as few bends as possible, and these
must be smoothly rounded with a minimum of 5 cm radius. (Fig.
9)
Sharp angles must not be present