Fig. 4 Tylö Steam Generator Home type, dimensions in millime-
ters
Fig. 5 Tylö Steam Generator Commercial type, dimensions in
millimeters
Dimensional informationOutlet vent
Must be placed high on a wall or on the ceiling and as far from
the inlet vent as possible, although not above the door or at a se-
ating location. The outlet vent must be connected to a ventilation
duct to take the air outdoors. An existing duct could be utilized.
The ventilation duct must be completely sealed and made of a
material that can tolerate high air humidity. Water pockets, where
condensed water can collect and cause blockages, must not be
present. If the ventilation duct must have a water pocket, a water
trap is installed to drain condensed water to a drain.
The size of the outlet vent depends on the requirement that it
must be able to evacuate 10-20 m³ air per person per hour.
Mechanical extraction
If extraction ventilation provided by the natural ventilation principle
is insuffi cient, perhaps due to low pressure in the room from which
air is supplied to the steam room, mechanical ventilation must be
connected and adjusted to extract a minimum of 10 and a maxi-
mum of 20 m³ per person per hour.
The steam generator functions:
All Tylö steam generators of the Home and Commercial type are
equipped with:
A stainless steel water tank
Volume of the water tank:
Home - 2 liters
Commercial - 8.4 liters
Acid-proof stainless steel tube elements
Automatic emptying 60 minutes after the steam bath has
been switched off
Automatic fl ushing clean after emptying
3-division output
Electronic water level regulation
Electronic level protection
Limescale removing self-cleaning electrodes
Continuous steam production
Always the correct power, regardless of the water quality and
level
Built-in safety valve
Built-in temperature protection
Built-in dirt fi lter
Automation for remote control
Rinse-proof design
IP class 23
Fault code clearing
Automatic emptying
Non-return valve
Backfl ow protection
Correct power rating, related to room volume:
kW
Steam room volume min./max. m³
Steam
prod.
kg/h
Toughened glass
lightweight wall. Im-
pression, Panacea,
etc.
Tiled, concre-
te, stone, etc.
heavyweight wall.
with
ventila-
tion
without
ventila-
tion
with
ventila-
tion
without
ventila-
tion
3 - max. 3 - max. 2 3,5
6 3-8 4-15 2-5 2,5-8 8
9 6-16 13-24 4-10 7-16 12
12 14-22 22-30 8-15 14-20 16
15 18-25 28-38 10-19 18-25 20