Tylo Commercial 9 kW - User Manual

Tylo Commercial 9 kW
114 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TYLÖ STEAM
HOME / COMMERCIAL
2017-03-29
2900 4160
SVENSKA
INSTALLATION-/BRUKSANVISNING
ENGLISH
INSTALLATION/USER GUIDE
FRANÇAIS
INSTALLATION/MODE D’EMPLOI
РУССКИЙ
РУКОВОДСТВО ПО УСТАНОВКЕ/ЭКСПЛУАТАЦИИ
DEUTSCH
INSTALLATIONS-/BEDIENUNGSANLEITUNG
NEDERLANDS
INSTALLATIE-/GEBRUIKERSHANDLEIDING
POLSKI
INSTRUKCJA INSTALACJI/OBSŁUGI

Table of Contents

Questions and Answers

  • B
    bonnie92Aug 19, 2025
    Why is the Tylo Commercial 9 kW Iron steam room taking so long to heat up?
    • S
      Sean PotterSep 12, 2025
      If your Tylo Iron steam room is heating up slowly, consider these potential causes. A low power steam generator may be insufficient, suggesting a change to a higher power model. Excessive ventilation can hinder heating, so reduce it. Check for blown or tripped fuses in the distribution board and replace them. If the surrounding air temperature is below 15°C, raise it or switch to a more powerful steam generator. A broken pipe element will also slow heating and needs replacement. Lastly, ensure the sensor isn't too close to the steam; if it is, move it or adjust the steam jet's direction.
  • C
    Christopher SullivanAug 21, 2025
    What to do if hot water runs out through the Tylo Commercial 9 kW Iron steam nozzle with little steam?
    • B
      Bernard WaltersAug 22, 2025
      If hot water is running out of the Tylo Iron steam nozzle with little to no steam, the feed water solenoid valve may be jammed. Try removing and cleaning the solenoid valve, or address any electrical faults. If the solenoid valve is broken, replace it. Alternatively, there could be a circuit board fault, requiring replacement of the circuit board. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits are removed.
  • L
    Lindsey SmithAug 25, 2025
    Why is the desired temperature maintained in the Tylo Commercial 9 kW Iron steam room, but there is no steam?
    • P
      Pamela MoralesAug 25, 2025
      If your Tylo Iron steam room maintains the desired temperature but produces no steam, it could be due to several reasons. Insufficient ventilation may be the cause, so increase the amount of ventilation. If the incoming air temperature is too high, reduce it to a maximum of 35°C. Also, ensure that the surrounding temperature does not exceed 35°C. Finally, check the thermometer's location; it should be approximately 150-170 cm above the floor and away from the steam jet. If the thermometer is faulty, replace it.
  • B
    burnsconnieAug 28, 2025
    What causes loud banging in the water lines of a Tylo Iron when the solenoid valve opens or closes?
    • D
      dudleyscottAug 28, 2025
      Loud banging in the water lines of your Tylo Iron when the solenoid valve operates can be caused by a couple of issues. First, ensure the incoming water piping to the steam generator is securely fastened to the wall using clamps. If the banging persists, it could be due to recoil (water hammer) in the incoming water piping. To resolve this, replace about 1 meter of the water piping nearest the steam generator with a flexible type, such as an armored rubber hose capable of withstanding the water pressure.
  • J
    Jacob OrtizAug 30, 2025
    What causes steam production to come and go at short intervals in my Tylo Commercial 9 kW?
    • J
      Jason CarrollAug 31, 2025
      Inconsistent steam production in your Tylo Iron could be due to a couple of factors. Check the sensor's positioning relative to the steam; if it's not correct, move the sensor or change the direction of the steam jet. Also, inspect the dirt filter for limescale or foreign material, and remove and clean the dirt filter if necessary.
  • K
    Kerry RoweSep 2, 2025
    Why does hot water squirt jerkily out through the steam nozzle of my Tylo Commercial 9 kW Iron?
    • W
      William Hoffman MDSep 3, 2025
      If hot water squirts jerkily or trickles out of the Tylo Iron steam nozzle mixed with steam, it could be due to a small water pocket in the steam pipe; eliminate the water pocket. Alternatively, an excessive length of uninsulated steam pipe could be the cause, so insulate the steam pipe. Also, check for excessive deposits on the electrodes and clean them with a cloth until all deposits have been removed.
  • P
    Pamela BryantSep 6, 2025
    What causes the safety valve to open or temperature protection to trip on a Tylo Commercial 9 kW Iron?
    • T
      terryjessicaSep 6, 2025
      If the safety valve opens or the temperature protection trips on your Tylo Iron, it could be due to a few reasons. If the internal diameter of the steam piping is significantly reduced, change the pipe or joint component causing the reduction, ensuring a minimum internal diameter of 12 mm. If there are several sharp bends in the steam pipe, replace them with gently rounded bends (minimum radius 50 mm). Excessive limescale in the steam generator water can also cause this issue; descale several times, flushing in between. If that doesn't work, change the water tank, complete with the element and electrodes.
  • R
    Ryan SmithSep 8, 2025
    What to do if hot water runs continuously out from the Tylo Commercial 9 kW steam generator drain pipe?
    • W
      wilkinsnicoleSep 8, 2025
      If hot water continuously runs out from the Tylo Iron steam generator drain pipe, the automatic draining solenoid valve may be jammed. Switch off the steam generator and test again after 80 minutes. If the fault persists, remove the motorized ball valve for the automatic drain function and clean it.
  • M
    Mr. Frank Padilla DVMSep 12, 2025
    What to do if fan or lighting not working in Tylo Commercial 9 kW despite correct connections?
    • V
      Vanessa GuerreroSep 12, 2025
      If the fan or lighting in your Tylo Iron isn't working despite correct connections, a fuse may have blown or tripped. Replace the fuse.
  • R
    Robert CarlsonNov 15, 2025
    What to do if neither steam nor heat are present in the Tylo Commercial 9 kW steam room?
    • T
      taylor56Nov 15, 2025
      If there's no steam or heat in your Tylo Iron steam room, several issues could be the cause. First, check if the fuses in the distribution board have blown or tripped and replace them if necessary. Ensure water is entering the steam generator by opening the connected tap and inspecting the hose for kinks. Verify the control panel's time and temperature settings are correct. Also, inspect and clean the dirt filter connected to the incoming water line. Remove and clean the feed water solenoid valve to clear any blockages. If there's excessive limescale, replace the water tank, element, and electrodes. Confirm the steam generator is connected to the correct voltage, referring to the wiring diagram. Finally, a fault in the circuit board, control panel, or solenoid valve may require replacing t...

Summary

General Installation Setup

Steam Room Environment

Specifies requirements for the steam room environment, including temperature and insulation.

Steam Generator Installation Location

Details where to install the steam generator and required clearances for maintenance.

Temperature Cut-out and Floor Drainage

Covers the temperature cut-out function and steam room floor/drainage requirements.

Ventilation and Inlet Vent Requirements

Describes ventilation needs and the specification for the air inlet vent.

Generator Operation and Features

Outlet Vent and Mechanical Extraction

Details outlet vent connection and requirements for mechanical extraction.

Steam Generator Functions and Dimensions

Lists key generator features and provides dimensional information for models.

Pipework Installation

Water Supply and Steam Pipe Connections

Guides on connecting incoming water supply and the steam pipe, including material and diameter.

Drainage System Installation

Explains how to connect the drainage pipe, its temperature, and scale reduction options.

Electrical Installation and Wiring

Wiring Diagrams and Connection Terminals

Illustrates steam generator wiring and details connection terminals for various components.

Lighting, Thermistor, and Options

Covers lighting control, thermistor positioning, and optional external switches.

Home Automation and Multisteam Features

Explains home automation integration and connecting multiple steam generators.

Modular Connector Pin Configuration

Details the pin configurations and connections for modular components.

Connecting Components to Modular Contacts

Explains how to connect various units using modular contacts and their specifications.

Spare Parts Identification

Troubleshooting Common Issues

Initial Troubleshooting Checks and Fault Diagnosis

Provides initial troubleshooting steps and a list of common faults with remedies.

Steam Production and Water Flow Issues

Addresses issues with steam generation, hot water instead of steam, and jerky output.

Drain Pipe Noise and Water Line Hammer

Explains causes for continuous drain pipe flow and loud banging in water lines.

Safety Valve and Temperature Cut-out Faults

Details causes for safety valve activation or temperature cut-out tripping.

Intermittent Steam and Fan;Lighting Issues

Troubleshoots intermittent steam production and issues with fan or lighting operation.

Error Code Diagnostics and Solutions

Temperature and Level Sensor Error Codes

Diagnoses errors related to temperature sensors and water level electrodes.

Communication and Auto-Emptying Faults

Addresses communication loss with control panels/boards and faults in the emptying function.

Electrode, Unit, and Door Switch Errors

Covers errors for mid-level electrodes, too many units, and door switch malfunctions.

ROHS Environmental Compliance

Disposal and Recycling Instructions

Provides guidance on proper disposal and recycling of the product.

User Guide and Maintenance Procedures

Control Panel and Main Power Switch Operation

Describes the control panels and the operation of the main power switch.

Steam Generator Descaling Procedure

Details the process and importance of regular descaling to maintain performance and longevity.