Questions and Answers

  • A
    Amy Navarro MDSep 10, 2025
    What to do if Tylo Kitchen Appliances hot water runs from steam generator drain?
    • T
      Tina MyersSep 12, 2025
      If hot water is running continuously out from the drain pipe of your Tylo Kitchen Appliances steam generator, switch it off and wait 80 minutes before testing again. If the issue persists, remove the motorized ball valve for the automatic drain function and clean it.
  • S
    Shannon NguyenAug 23, 2025
    What to do if my Tylo STEAM HOME Iron steam room is taking too long to heat up?
    • D
      Darin BrownAug 23, 2025
      If your Tylo Iron steam room is taking an unusually long time to heat up, consider these potential causes and solutions: * If you have steam generator low power, change to a higher power steam generator. * Reduce the amount of ventilation to 10-20 m³ air per person per hour if there is too much ventilation in the steam room. * Replace any blown or tripped fuses in the distribution board. * If the surrounding air temperature is below 15°C, raise it or switch to a higher power steam generator. * Replace a broken pipe element. * Move the sensor or change the direction of the steam jet if the sensor has been placed too close to the steam.
  • S
    Shannon ClarkAug 25, 2025
    Why is my Tylo STEAM HOME safety valve opening or temperature protection cut-out tripping?
    • W
      William LarsonAug 26, 2025
      If the safety valve opens or the temperature protection cut-out trips on your Tylo Iron, it could be due to a drastically reduced internal diameter of the steam piping. Change the pipe or joint component causing the reduction (internal diameter min. 12 mm). Also, ensure that any bends in the steam pipe are gently rounded (minimum radius 50 mm). If excessive limescale is present in the steam generator water, descale several times with flushing in between. Change the water tank, complete with the element and electrodes, if that did not work.
  • P
    pamela15Aug 27, 2025
    What to do if hot water runs out through the steam nozzle of my Tylo STEAM HOME?
    • E
      Erika RodgersAug 27, 2025
      If hot water runs out through the steam nozzle of your Tylo Iron, with little to no steam, the feed water solenoid valve may have jammed due to dirt or an electrical fault. Remove and clean the solenoid valve or rectify the electrical fault. If the solenoid valve is broken, replace it. A circuit board fault may also be the cause, so change the circuit board. Clean the electrodes if there is too much deposit on them.
  • K
    Kimberly SandovalAug 27, 2025
    What to do if neither steam nor heat are present in my Tylo Iron steam room?
    • A
      April HancockAug 27, 2025
      If your Tylo Iron steam room lacks both steam and heat, start by checking the fuses in the distribution board and replace them if necessary. Ensure water is entering the steam generator by opening the connected tap and inspecting the hose for kinks. Verify the time and temperature settings on the control panel. Clean the dirt filter connected to the incoming water to remove any obstructions. Also, clean the feed water solenoid valve to clear any foreign particles. If there's excessive limescale, replace the water tank, element, and electrodes. Check the voltage and generator connections against the wiring diagram. If there's a fault in the circuit board, control panel, or solenoid valve, replace the faulty component. Finally, replace the pipe element if it is broken.
  • S
    Sharon ShawAug 29, 2025
    How to fix loud banging in the water lines of my Tylo STEAM HOME Iron?
    • J
      Justin ReedAug 29, 2025
      If you hear loud banging in the water lines of your Tylo Iron when the solenoid valve opens or closes, ensure the incoming water piping to the steam generator is firmly secured to the wall using clamps. If there is recoil (water hammer) in the incoming water piping, replace 1 meter of the water piping closest to the steam generator by a flexible type, e.g. armored rubber hose that can withstand the water pressure.
  • S
    Stephen HarrisSep 18, 2025
    Why does Tylo Kitchen Appliances steam production come and go?
    • B
      Brandon GarzaSep 18, 2025
      If steam production in your Tylo Kitchen Appliances appliance comes and goes at short intervals right from the start: * Move the sensor or change the direction of the steam jet to ensure correct positioning relative to the steam jet. * Remove and clean the dirt filter to eliminate limescale or other foreign material.
  • J
    Jodi CarterSep 22, 2025
    What if fan is not working in Tylo Kitchen Appliances?
    • C
      Cody MorrisSep 22, 2025
      If the fan or lighting isn't working in your Tylo Kitchen Appliances appliance despite correct connections, replace the fuse as shown in Fig. 15.
  • S
    Sarah MosleySep 8, 2025
    How to fix no steam in Tylo Kitchen Appliances steam room at correct temperature?
    • C
      carpenterannaSep 9, 2025
      If the desired temperature (40-50°C) is maintained in your Tylo Kitchen Appliances steam room but there's no steam, check these potential issues: * Increase the ventilation in the steam room. Ensure the air exhaust valve extracts 10-20 m³ of air per person per hour. * Reduce the incoming air temperature to a maximum of 35°C. * Make sure the surrounding air temperature does not exceed 35°C. * Ensure the thermometer is located approximately 150 - 170 cm above floor level and away from the steam jet.
  • D
    dwayne52Sep 4, 2025
    Why are the fan and lighting not working in my Tylo STEAM HOME Iron?
    • M
      Maria FieldsSep 4, 2025
      If the fan or lighting in your Tylo Iron is not working despite correct connections, a fuse may have blown or tripped. Replace the fuse.

Summary

General Installation and Operation

Generator Placement and Installation

Floor and Drain Specifications

Regular Descaling and Maintenance

Instructions and schedule for removing limescale build-up from the generator.

Pipework Installation Guide

Incoming Water Connection

How to connect the incoming water supply to the steam generator.

Steam Pipe Routing and Installation

Drainage Pipe Routing

Requirements for the steam generator drain pipe, including slope and material.

Electrical Installation and Wiring

Steam Room Wiring Diagram

Troubleshooting Guide

Initial Troubleshooting Checks

Basic troubleshooting steps and common fault causes in the steam room.