21
Location of steam generator
Installation must be carried out by an authorized electrician
and authorized plumber. The steam generator must be
securely connected. It is installed outside the steam room but
as close to it as possible. The maximum length of the steam
pipe is 15 meters.
Take care to respect the specified installation distances (Fig.
2). These have been defined to permit maintenance and
servicing.
Fig. 2
The steam generator is to be located in a dry and ventilated
space with drainage, above, below or on the same level as
the steam room. (Never directly above a drain, or into an
aggressive environment.) The maximum difference in height
between the steam generator and the steam room is 3
meters. (Fig. 3)
Fig. 3
The steam generator must be installed horizontally, at such a
height above the floor so that the drainage pipe will have a
good fall to its drain.
Control panel
User guide: supplied with control panel. The steam generator
is controlled electronically by the following compatible
models:
Elite Wifi - the Tylö Elite Wifi control panel has a processor
and an operative system which enables many advanced
functions. In addition to a number of personal settings, the
Elite can also be programmed to suit your personal
timetable. Added to this are such functions as extra fans,
fragrance pumps and lighting. The panel has energy-saving
functions and the possibility of connection to a wireless
network. It can be located inside or outside the steam room.
Elite - the Tylö Elite control panel includes the same
functions as the Elite Wifi, except that it cannot be connected
to a wireless network with app functionality. It can be located
inside or outside the steam room.
Pure - Touch panel with basic functions, to be located inside
or outside the steam room.
Temperature cut-out
The steam generator is equipped with a built-in temperature
cut-out. If the cut-out has activated, find and rectify the fault
with the aid of the fault tracing list in these instructions.
Main power switch
The main power switch is located on the underside of the
steam generator (Fig. 4) (Fig. 5). It should only be used
when the system will be disconnected for a long period.
The automatic emptying function of the steam generator will
stop if the power supply is disconnected for any reason.
Fig. 4